Inspections for the day of: Wednesday, February 19, 2020.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-00685 Rough-in2/19/20202/19/20202/19/2020 3:46:47 PMPPASS
Please call contractor 30 minutes in advance for access at ###-#### and call Ryan with questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum
-R/I ok
MEC20-00602 Final2/18/20202/19/20202/19/2020 3:44:12 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- final ok
MEC20-00699 Final2/19/20202/19/20202/19/2020 3:00:51 PMPNH
Inspection requested via web by Margie Rowe
- no access left notice on front door
MEC20-00233 Final2/12/20202/19/20202/19/2020 2:47:15 PMPPASS
Homeowner Joel Santarone ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- final ok
MEC19-04898 Rough-in2/19/20202/19/20202/19/2020 2:25:11 PMPPART
301
- vent pipe clearances to framing ok
- need to see clearances with insulation installed
- vent piping specs should be followed for enclosure. having an access door to the vent and a b vent tee at the bottom for clean out
MEC20-00300 Rough-in2/19/20202/19/20202/19/2020 2:07:31 PMPFAIL
This is a duct work inspection only. Joe our installer will be there from 8:15 am -2 pm Phone #: ###-#### Inspection requested via web by Devry King
- changes to HVAC need to be submitted to city for review
- will need to see gas pressure test on new gas line
- water heater flue needs 1" clearances and insulation shield installed
- exhaust fans in showers need installed
MEC20-00613 Final2/18/20202/19/20202/19/2020 1:18:40 PMPFAIL
Please call ahead to Ben when headed to residence. He will not be home until 12:30pm Phone #: ###-#### Inspection requested via web by Sarah Small
- A/C fuses need to 25 amp
- A/C service port locking caps
- pictures of corrections will be acceptable
MEC20-00444 Rough-in2/18/20202/19/20202/19/2020 11:01:12 AMAFAIL
insulation inspection Phone #: ###-#### Inspection requested via web by Dave Sorensen
- outside air duct needs insulated
MEC20-00335 Rough-in2/18/20202/19/20202/19/2020 10:41:53 AMACANC
consult - Cyrus Phone #: ###-#### Inspection requested via web by Brandon Sorensen
MEC20-00335 Conference2/19/20202/19/20202/19/2020 10:41:44 AMAPASS
consult - Cyrus Phone #: ###-#### Inspection requested via web by Brandon Sorensen
MEC19-05795 Final2/18/20202/19/20202/19/2020 9:54:21 AMAPASS
Phone #: ###-#### Inspection requested via web by Lindsey Stegemann
- fireplace final ok
MEC20-00476 Final2/14/20202/19/20202/19/2020 9:53:58 AMAFAIL
Call Chris in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout
- A/C need locking caps
- line set penetration into cover needs sealed
- b vent needs 1" clearances
- condensate line needs supported
- will need install crew onsite to gain access to attic to furnace
- talked with homeowner about getting a plumbing permit for plumbing vent that terminates in attic
MEC20-00692 Rough-in2/18/20202/19/20202/19/2020 9:13:49 AMAFAIL
Call for lock box code Phone #: ###-#### Inspection requested via web by Sean Hyten
- all CSST in crawl needs supported per spec
- need BTU information on range
- only one appliance flex connector can be used on range gas line
- gas piping connection to meter on north side looks to be under a car port and will need a crash bar/ protection post installed
- 1/2 CSST gas pressure test fail gauge would not zero out
- 5lb flue pressure test for water heater ok
- 20lb gas pressure test to water heater ok
MEC20-00423 Final2/18/20202/19/20202/19/2020 8:18:51 AMAPASS
We sent pictures to Jack and he said he would pass it once he saw the corrections from the photos we sent. Phone #: ###-#### Inspection requested via web by Arielle
Hendricks
- final ok
MEC19-01851 Mec-Aging Inspection2/19/20202/19/20202/19/2020 8:15:57 AM FAIL
Permit has not been active since 5-10-19 when it passed a R/I inspection. Need to schedule final inspection with owner if ready. Permit will expire at next mechanical aging inspection if not active.
MEC19-03463 Mec-Aging Inspection2/19/20202/19/20202/19/2020 8:14:25 AM PASS
Doc Permit Finaled ok
MEC19-03463 DOC - Permit Finaled2/19/20202/19/20202/19/2020 8:14:11 AMAPASS
Doc Permit Finaled
MEC19-01842 Mec-Aging Inspection2/19/20202/19/20202/19/2020 8:13:14 AM FAIL
Permit has not been active since 5-31-19 when it failed final inspection. Add items to permit for final. Permit will expire at next mechanical aging inspection if not active.
MEC19-01841 Mec-Aging Inspection2/19/20202/19/20202/19/2020 8:00:32 AM FAIL
Permit has not been active since failing inspection on 7-5-19. If corrections have been made schedule inspection with owner. Permit will expire at next mechanical aging inspection if not active.
MEC19-01845 Mec-Aging Inspection2/19/20202/19/20202/19/2020 7:58:10 AM PASS
WIP