ELE06-00192
| Rough-In Permanent Service | 2/1/2006 | 2/2/2006 | 2/2/2006 3:16:03 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 2/1/2006 at 4:25:43 PM. Contact: ###-####. r/i walls ceilings ok p/s u/g new ok
|
ELE05-04546
| Rough-In Permanent Service | 2/2/2006 | 2/2/2006 | 2/2/2006 3:15:19 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 2/2/2006 at 9:53:02 AM. Contact: ###-####. walls soffits ceilings core shell ok p/s u/g new ok
|
ELE06-00190
| Rough-In Permanent Service | 2/1/2006 | 2/2/2006 | 2/2/2006 3:12:31 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 2/1/2006 at 4:29:43 PM. Contact: ###-####. r/i walls ceilings ok p/s u/g new ok
|
ELE06-00386
| Temporary Service | 2/2/2006 | 2/2/2006 | 2/2/2006 2:14:51 PM | P | PASS |
|
|
Aaron ###-#### called contractor about clearence for drip loop t/s o/h new ok
|
ELE06-00285
| Electrical Rough-In | 2/2/2006 | 2/2/2006 | 2/2/2006 1:46:46 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 2/2/2006 at 8:43:37 AM. Contact: ###-####. r/i ok bot units
|
ELE05-03900
| Rough-In Permanent Service | 2/1/2006 | 2/2/2006 | 2/2/2006 1:31:13 PM | A | FAIL |
|
|
requests after 10am please//weston hatch ###-#### please call 15 prior to meet you, if no answer said he will be at the house already cor. do not cover posted met owner 230.28 guy for mast, also meter too high,210.11 c 3 bath rm shall feed only bath rm, 300.10 314.22 bond flex and metal on WH plastic box or do it another way,300.4 nail plates 11/4" everywhere, 314.16 box fill everywhere, 300.14 6" free lenght everywhere, 250.148 grd screws and splice all equip. grds together, 314.17 sheath shall extend 1/4" into box, 312.5 conn for GEC at p/s, 250.104 bond hot & cold water,110.3 install acorn grd clamp properly COW, told owner about creating more violations permit may be voided, if garage is not covered protect romex, install all boxes, complete all makeup, pull recepts and switches from boxes
|
ELE06-00329
| Electrical Rough-In | 2/1/2006 | 2/2/2006 | 2/2/2006 9:51:22 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: joe wheeler corrections made r/i ok
|
ELE05-03999
| Final | 2/1/2006 | 2/2/2006 | 2/2/2006 9:25:22 AM | A | PART |
|
|
Please call Bobby Langner ###-####; Phone #: ###-#### x39 Internet Inspection Request from: Kristopher wilson t/o ok card signed xray unit shall not be used till listing questions answered xray tube not listed, electrician turnrd power off
|
ELE06-00289
| Rough-In Permanent Service | 2/1/2006 | 2/2/2006 | 2/2/2006 9:21:33 AM | A | NR |
|
|
steve; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa called
|
ELE05-04222
| Final | 2/2/2006 | 2/2/2006 | 2/2/2006 12:00:00 AM | A | PASS |
|
|
called contractor canceled and will not be doing work
|