Inspections for the day of: Friday, February 2, 2007.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBill VanDegrift
TitlePLM-INSPECTOR
Phone #794-9372
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC06-03767 Rough-in2/1/20072/2/20072/2/2007 5:09:03 PMPFAIL
call monte to let him know you are on your way. Phone #: ###-#### 4-20# gas tests ok. seal holes in return air plenum( fire sprinkler piping) 1st floor north west unit. repair line set insulation. hang iron pipe gas piping on 1st floor every 10'. seal range hood boots( connection to hood) 3rd floor. nail plate line sets. fire place flue touching flex duct 3rd floor north side. verify with Dixie---(1) water heater/furnace flue piping. (2)condensate termination for common area air handler. (3)duct sealing and insulation for metal duct work in garage ceilings.
MEC06-02661 Final2/2/20072/2/20072/2/2007 3:37:38 PMPFAIL
Thanks, Andrea. Phone #: ###-#### x0000 no corrections made
MEC07-00398 Rough-in2/2/20072/2/20072/2/2007 2:54:49 PMPPART
Phone #: ###-#### ri ok to cover just needs condensate from furnace ran. 20# test ok
MEC07-00397 Rough-in2/2/20072/2/20072/2/2007 2:54:04 PMPPASS
Phone #: ###-#### RI OK 20# TEST ok
MEC06-02699 Final2/2/20072/2/20072/2/2007 2:29:41 PMPPASS
MEC06-02772 Final2/1/20072/2/20072/2/2007 2:29:21 PMAPASS
Phone #: ###-####
MEC06-03626 Final2/1/20072/2/20072/2/2007 1:54:31 PMAPASS
dwayne; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
MEC04-02369 Final2/2/20072/2/20072/2/2007 1:41:25 PMPPASS
###-#### jerry pls call for key location
MEC07-00150 Pressure Test2/1/20072/2/20072/2/2007 1:24:48 PMAPASS
Phone #: ###-#### 20# test ok
MEC07-00150 Rough-in2/1/20072/2/20072/2/2007 1:22:41 PMAFAIL
Phone #: ###-#### 30" service platform required infront of the furnace in the attic. 20# test ok
MEC07-00365 Final2/1/20072/2/20072/2/2007 11:53:10 AMAPASS
PLEASE SCHEDULE PRESSURE TEST FOR AM, HOMEOWNER WOULD LIKE A CALL WHEN YOU''RE ON YOUR WAY Phone #: ###-#### 20# test ok
MEC07-00389 Final2/1/20072/2/20072/2/2007 11:40:26 AMACANC
PAGER #99105 Phone #: ###-#### set it up for monday, troys out
MEC06-03820 Final2/1/20072/2/20072/2/2007 10:16:13 AMAPASS
Hi Dixie, if you go in house through garage door and go right to the stairs and go upstairs, turn left and go down hallway and turn left again and go down that hallway to the end, the bedroom on the right has attic access in closet. Builder is leaving a ladder at the closet for you to use. Please call me if you need an access code. Thank You! Phone #: ###-####
MEC07-00371 Rough-in2/1/20072/2/20072/2/2007 9:53:07 AMAPART
J0hn Note: partial final; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles partial ri ok south west corner
PLM07-00298 Water and/or Sewer2/1/20072/2/20072/1/2007 4:39:50 PMAPASS
Phone #: ###-#### partial sewer was covered prior to inspection, camera looked ok. replaced from stub around big tree about 15' total.
PLM07-00299 Water and/or Sewer2/1/20072/2/20072/1/2007 4:36:46 PMAPASS
baimbridge; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles sewer and water services ok do not cross property line
PLM07-00295 Water and/or Sewer2/1/20072/2/20072/1/2007 11:58:37 AMPCANC
Please call Kin at ###-#### atleast 1/2 hr before arrival of inspection. Works during the day and must be notified a head of time Phone #: ###-#### Inspection cancelled from web by: Mike Dunson