Inspections for the day of: Wednesday, February 20, 2013.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01271 Final2/20/20132/20/20132/20/2013 4:30:58 PMPFAIL
eric Phone #: ###-####
Weather proof in use cover needed for up deck receptical. Up blue bed open ground on circuit. Up white bed smoke detector power cold. Straps required on AC whip. Miss wire at AC disconnect, line/ load. Lock out or disconnect required for water heater circuit. Insulating bushing needed for flourescent fixture over stair to basement.
ELE12-02990 Final2/20/20132/20/20132/20/2013 3:54:17 PMPFAIL
call builder--brilliant services at ###-#### for access. Phone #: ###-#### >> Inspection requested via web by ron spen cer
Sprinkler box on back of house not secured with exposed 120 volt wiring sxposed.
ELE13-00310 Electrical Rough-In2/20/20132/20/20132/20/2013 3:01:17 PMPPASS
Tim-Please call at least 30 mins prior to inspection Phone #: ###-#### This permit for basement only. Basement rough in ok cover
ELE13-00300 Electrical Rough-In2/20/20132/20/20132/20/2013 2:45:49 PMPPASS
lee Phone #: ###-#### Ground whips needed in metallic boxes, mudrings on boxes mounted on wall with finished drywall. Corrections made. Rough in ok cover
ELE13-00298 Rough-In Permanent Service2/19/20132/20/20132/20/2013 2:11:20 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey
Wiring not finished around fireplace, ground all 3/0 boxes, secure AC wire where it stubs out, nail plates needed up utility, under stairs, above 3-gang box down stairs.
ELE13-00143 Final2/19/20132/20/20132/20/2013 12:47:03 PMPPASS
Please provide a final inspection for this project. Thank you, and have an awesome day! Phone #: ###-#### >> Inspection requested via web by Kevin Perez Final ok
ELE13-00352 Conference2/19/20132/20/20132/20/2013 10:53:23 AMADONE
After 10AM - Dan Phone #: ###-####
Discussed existing panel located in stairway. contractor shall relocate to provide work space.
ELE12-02865 Final2/19/20132/20/20132/20/2013 10:30:27 AMAPASS
Please call me half an hour before inspection to insure access thanks shaun ###-#### Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Final ok
ELE12-02982 Electrical Rough-In2/19/20132/20/20132/20/2013 10:10:37 AMAPASS
Tony Phone #: ###-#### Parking garage east central pour rough in ok cover
ELE12-02024 Electrical Rough-In2/19/20132/20/20132/20/2013 10:08:10 AMAPASS
Dave. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy
Area a underground rough in ok cover
ELE13-00353 Rough-In Permanent Service2/19/20132/20/20132/20/2013 8:54:58 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Stephen Kren Rough in ok cover p/s u/g n ok
ELE13-00300 Electrical Rough-In2/19/20132/20/20132/19/2013 11:58:46 AMPCANC
Lee Phone #: ###-#### or Matt ###-#### not ready