ELE14-03235
| Final | 2/20/2015 | 2/20/2015 | 2/20/2015 2:00:28 PM | P | FAIL |
|
|
Ron Phone #: ###-#### 250.32 Building supplied by feeder or branch circuit shall have a grounding electrode system 225.32 Seperate building, disconnecting means shall be installed at nearest point of entrance of conductors 250.104 (C) Structural Metal. Exposed structural metal that is interconnected to form a metal building frame and is not intentionally grounded or bonded and is likely to become energized shall be bonded to the service equipment enclosure;
|
ELE15-00431
| Final | 2/20/2015 | 2/20/2015 | 2/20/2015 12:47:33 PM | P | PART |
|
|
Partial - Rocky Phone #: ###-#### removed a piece of romex that was feeding an outet outside of bathroom, replaced GFI and outlet with new TR receptacles. Partial Final, first floor rooms 129, 131, 133, 134, 135, 136, 137, 138, 140, 142, second floor rooms 229, 234
|
ELE14-02485
| Final | 2/18/2015 | 2/20/2015 | 2/20/2015 12:08:10 PM | P | PASS |
|
|
FInal OK
|
ELE15-00442
| Final | 2/20/2015 | 2/20/2015 | 2/20/2015 12:07:20 PM | P | CANC |
|
|
needed PS inspection
|
ELE15-00442
| Permanent Service | 2/20/2015 | 2/20/2015 | 2/20/2015 12:06:31 PM | P | PASS |
|
|
P/S, O/H, R/C, OK
|
ELE14-03201
| Final | 2/19/2015 | 2/20/2015 | 2/20/2015 10:54:05 AM | A | FAIL |
|
|
james is the contact at ###-#### Phone #: ###-#### Inspection requested via web by Tracy Robertson called James 408.4 every circuit shall be labeled clear, evident, specific purpose- unit 104 210.12 A arc fault protection required for outlets in dwelling bedrooms 314.21 non combustible materials shall be repaired so no gap greater than 1/8 inch at edge of boxes- drywall gaps around panels BCC 4.05.26 Trim out inspections require all items to be functional, outlets not working in kitchen unit 103
|
ELE11-00879
| ELE-Aging Inspection | 2/20/2015 | 2/20/2015 | 2/20/2015 9:38:10 AM | | DONE |
|
|
Waiting to schedule for final
|
ELE15-00401
| Final | 2/13/2015 | 2/20/2015 | 2/20/2015 9:37:24 AM | A | PASS |
|
|
Their office opens at 830 am. Phone #: ###-#### Inspection requested via web by Dan Mitchell Final OK
|
ELE15-00401
| Electrical Rough-In | 2/13/2015 | 2/20/2015 | 2/20/2015 9:37:01 AM | A | PASS |
|
|
Their office opens at 830 am. Phone #: ###-#### Inspection requested via web by Dan Mitchell RI OK
|
ELE14-02485
| Final | 2/18/2015 | 2/20/2015 | 2/20/2015 9:24:40 AM | A | CANC |
|
|
Call Bill first ###-#### Phone #: ###-#### Inspection requested via web by Bill Litzebauer needed PM, not AM i
|
ELE13-02226
| Final | 2/19/2015 | 2/20/2015 | 2/20/2015 9:22:02 AM | A | CANC |
|
|
Dean// please call before Phone #: ###-#### This was a conference inspection, not final, discussed securing of romex at box entrances before cover
|
ELE15-00053
| Electrical Rough-In | 2/20/2015 | 2/20/2015 | 2/20/2015 8:55:33 AM | A | PASS |
|
|
Floor heat inspection in the laundry room. Thank You Phone #: ###-#### Inspection requested via web by Eric Brown Floor heat, laundry room ok to cover
|
ELE15-00159
| Electrical Rough-In | 2/19/2015 | 2/20/2015 | 2/20/2015 8:39:43 AM | A | PASS |
|
|
Bonding for mesh in concrete. Phone #: ###-#### Inspection requested via web by Kotton Corder OK to cover
|