Inspections for the day of: Wednesday, February 20, 2019.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-00499 Electrical Rough-In2/19/20192/20/20192/20/2019 3:28:28 PMPPASS
Please call 1\2- 1 hour before you go. I would like to walk through to show you all we did. Phone #: ###-#### Inspection requested via web by Greg Idsinga
Kitchen, master bed and bath wih floor heat in bath and closet rough in ok cover
ELE19-00241 Electrical Rough-In2/19/20192/20/20192/20/2019 2:37:45 PMPPART
Contact: Dan Schmidt Phone #: ###-#### Inspection requested via web by Deb Gooden Walls except cafe rough in ok cover
ELE18-01929 Final2/15/20192/20/20192/20/2019 1:41:18 PMPPART
Phone #: ###-#### Inspection requested via web by Alan Lusk
110.8, 11,27(B), 300.3(A)- Exposed conductors running in and out of meter bases shall be installed in a recognized wiring method of chapter 3.
230.70(A)(1)- Main disconnecting means of service shall be on exterior of building or immediately on inside.
BCC 4 05 31(C)- Unfused conductors shall not enter a structure unless underground fed with a max of 4 1/2' in length.
240.24- Over current devices shall not be installed over stairs.
Service reconnect was granted on temporary basis so other tenants would not be without power for an extended period of time.
60 amp feeds to each apartment ok to remain if no changes done to apartments.
Complete service change is required.
Unit 4 tested ok. TCO ok
ELE18-04858 Final2/19/20192/20/20192/20/2019 12:53:05 PMPPASS
inspection Phone #: ###-#### Inspection requested via web by David Feller
Final ok
ELE18-04702 Electrical Rough-In2/19/20192/20/20192/20/2019 11:26:37 AMAPASS
There is a lock box on the back shop door, code 2020. If you have any questions please feel free to contact Luke ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan
Discussed with contractor service calculation results in approx. 140 amp minimum service needed for an additional branch circuit for hot tub. Contractor to increase service or prove calculation less than what exists by final.
House rewire rough in ok cover
ELE19-00408 Electrical Rough-In2/19/20192/20/20192/20/2019 10:43:19 AMAPASS
Contact: Josh Mangum Phone #: ###-#### Inspection requested via web by Deb Gooden Bar walls rough in ok cover
ELE18-01608 Electrical Rough-In2/19/20192/20/20192/20/2019 10:05:25 AMAPASS
Common area ceiling inspection, Building D7 Phone #: ###-#### Inspection requested via web by Mike McCarrel
Service inspection to be requested for main distibution panel all sub- feeds to be installed as needed. D-7 ceiling rough in ok cover
ELE19-00154 Final2/19/20192/20/20192/20/2019 6:33:49 AMACANC
code 2468 Phone #: ###-#### >> Inspection requested via web by Icon Electric Inspection cancelled from web by: Icon Electric