Inspections for the day of: Tuesday, February 21, 2006.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-00610 Rough-In Permanent Service2/21/20062/21/20062/21/2006 4:25:16 PMPPASS
ron ###-#### ric ok, p/s u/g n ok
ELE05-04238 ELE-Aging Inspection2/21/20062/21/20062/21/2006 4:18:46 PM DONE
see final
ELE06-00604 Electrical Rough-In2/21/20062/21/20062/21/2006 4:17:25 PMPCANC
Stacy -- for hot tub; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong see final
ELE06-00607 Rough-In Permanent Service2/21/20062/21/20062/21/2006 3:19:42 PMPFAIL
Brandon; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong called contr, left corr notice, 300.4(A) edge of hole shall be 1/14" from edge of framing member, 334.80 when more than 2 nm conductors pass thru hole to be fire-stopped, ampacity shall be adjusted per 310.15(B)(2)(a), 314.20 box shall be flush with combustible material, 334.30 nm cable shall be supported within 12" of box
ELE06-00232 Electrical Rough-In2/20/20062/21/20062/21/2006 3:08:29 PMPNR
This is for a wall inspection, call Ryan with any questions. ###-####; Phone #: ###-#### Internet Inspection Request from: Daniel Gamboa met elec, nr
ELE06-00569 Final2/16/20062/21/20062/21/2006 1:57:30 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Dana Moyer ok to final
ELE05-04605 Final2/21/20062/21/20062/21/2006 1:16:33 PMPPASS
Tom; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong called office to correct address, corrections made, signed occ card, ok to final
ELE06-00150 Electrical Rough-In2/21/20062/21/20062/21/2006 12:55:24 PMPPASS
ceiling insp jerimiah; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie outer offices and halls ok for ceiling tiles
ELE06-00584 Temporary Service2/17/20062/21/20062/21/2006 9:54:00 AMAFAIL
###-#### rick called contr, left message, left corr notice, 312.5 conductors entering enclosures shall have abrasion protection, 110.12(C) there shall be no broken parts
ELE06-00329 Final2/20/20062/21/20062/21/2006 9:25:55 AMAPASS
Phone #: ###-#### Internet Inspection Request from: joe wheeler ok to final, signed occ card
ELE05-03599 Final2/20/20062/21/20062/21/2006 8:38:34 AMAPASS
Scheduled by a contractor via Hello! on 2/20/2006 at 5:13:29 PM. Contact: ###-####. corr made, ok to final
ELE06-00592 Permanent Service2/21/20062/21/20062/21/2006 8:15:59 AMPPASS
please call first; Phone #: ###-#### Internet Inspection Request from: Todd Holbrook p/s n exst meter pak ok
ELE06-00592 Electrical Rough-In2/21/20062/21/20062/21/2006 8:14:54 AMAPASS
please call first; Phone #: ###-#### Internet Inspection Request from: Todd Holbrook walls only ok to cover
ELE05-04205 Final2/21/20062/21/20062/21/2006 12:00:00 AMAPASS
ok to final
ELE05-04234 Final2/21/20062/21/20062/21/2006 12:00:00 AMAPASS
looked at signs, ok to final
ELE06-00604 Final2/21/20062/21/20062/21/2006 12:00:00 AMPPASS
Stacy -- for hot tub; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong called contr to gnd downspout, ok to final
ELE05-04238 Final2/21/20062/21/20062/21/2006 12:00:00 AMPPASS
looked at sign, ok to final
ELE05-04233 Final2/21/20062/21/20062/21/2006 12:00:00 AMPPASS
looked at sign, ok to final