ELE14-00427
| Electrical Rough-In | 2/21/2014 | 2/21/2014 | 2/21/2014 3:18:49 PM | P | PASS |
|
|
Mike Phone #: ###-#### ri ok
|
ELE13-03554
| Electrical Rough-In | 2/21/2014 | 2/21/2014 | 2/21/2014 2:42:27 PM | P | PASS |
|
|
Please call ahead for access/before 3 - Mike Phone #: ###-#### ri ok
|
ELE14-00402
| Electrical Rough-In | 2/19/2014 | 2/21/2014 | 2/21/2014 2:41:32 PM | P | PASS |
|
|
Contact Tom for instructions. Phone #: ###-#### >> Inspection requested via web by Tina Payne u/ gonly ok cover
|
ELE14-00414
| Electrical Rough-In | 2/20/2014 | 2/21/2014 | 2/21/2014 2:09:58 PM | P | PASS |
|
|
We are requesting a partial wall rough-in inspection for tomorrow 2/21 our onsite contact is Chris Ankrom ###-####. Thank you. Phone #: ###-#### >> Inspection requested via web by Clint Tate walls re-done south part only ok cover, said no more 1-side
|
ELE14-00028
| Final | 2/21/2014 | 2/21/2014 | 2/21/2014 1:39:34 PM | P | PASS |
|
|
Mike Phone #: ###-#### ok final
|
ELE14-00384
| Final | 2/21/2014 | 2/21/2014 | 2/21/2014 12:52:10 PM | P | PASS |
|
|
call Art with questions Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack ok final
|
ELE13-03457
| Final | 2/20/2014 | 2/21/2014 | 2/21/2014 12:28:59 PM | P | FAIL |
|
|
Garage code-9165 Phone #: ###-#### >> Inspection requested via web by Greg Traudt called, shall have access to garage, not in process of painting, add receptacle in library, downstairs box, strap flex in equipment room, blank off receptacle on island with 6" overhang, mbr receptacles shall be added adjacent to sinks
|
ELE14-00418
| Permanent Service | 2/20/2014 | 2/21/2014 | 2/21/2014 10:28:45 AM | A | FAIL |
|
|
Call for access code Phone #: ###-#### >> Inspection requested via web by Rick Beckman called, service lb broken, 50A breaker feeding 30A receptacle, receptacle shall fit in panel, told fix and recall
|
ELE14-00425
| Electrical Rough-In | 2/20/2014 | 2/21/2014 | 2/21/2014 9:59:30 AM | A | PASS |
|
|
call prior to arrival for access please. Phone #: ###-#### >> Inspection requested via web by Patrick Paz ok cover floor heat
|
ELE14-00423
| Rough-In Permanent Service | 2/20/2014 | 2/21/2014 | 2/21/2014 9:42:33 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Alan Lusk ri ok, p/s u/g n ok
|
ELE13-03528
| Final | 2/20/2014 | 2/21/2014 | 2/21/2014 9:09:29 AM | A | PASS |
|
|
Garage door entrance code 1979E. Phone #: ###-#### >> Inspection requested via web by Alan Lusk ok final
|
ELE14-00421
| Electrical Rough-In | 2/20/2014 | 2/21/2014 | 2/21/2014 8:48:30 AM | A | PASS |
|
|
Brandon Phone #: ###-#### walls ok cover
|
ELE14-00091
| Final | 2/20/2014 | 2/21/2014 | 2/21/2014 8:34:33 AM | A | PART |
|
|
I need a final so thay can get a temperary c of o thanks >> Inspection requested via web by Kevin Oderkirk ok all but furniture, signed t/o card
|