Inspections for the day of: Tuesday, February 21, 2017.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD16-04194 BLD-Framing/Rough-in2/21/20172/21/20172/21/2017 4:57:08 PMPPASS
Jamie-call 30 minutes prior to meet Phone #: ###-####. Interior steel stud framed walls ok.
BLD17-00308 BLD-Final2/18/20172/21/20172/21/2017 4:56:46 PMPDONE
Phone #: ###-#### Inspection requested via web by mark bedard
BLD17-00308 DOC - Permit Finaled2/21/20172/21/20172/21/2017 4:56:41 PMPPASS
BLD16-03129 BLD-Wall Bracing2/21/20172/21/20172/21/2017 4:56:34 PMPPART
Brett Phone #: ###-####. Install the missed blocking 2nd. floor behind the tub and nail.
BLD17-00071 BLD-Final2/21/20172/21/20172/21/2017 3:28:22 PMPPASS
Call half before // Shannon Phone #: ###-####
BLD17-00071 DOC - Permit Finaled2/21/20172/21/20172/21/2017 3:28:08 PMPPASS
BLD16-04163 BLD-Footing2/20/20172/21/20172/21/2017 2:46:15 PMPPASS
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
BLD16-00856 BLD-Final2/21/20172/21/20172/21/2017 2:03:37 PMPPASS
Call to meet there // Victor Phone #: ###-####. ok for perm occ.
BLD15-02707 BLD-Framing/Rough-in2/21/20172/21/20172/21/2017 1:45:05 PMPCANC
BLD15-02707 BLD-Framing/Rough-in2/17/20172/21/20172/21/2017 1:44:45 PMADONE
John Phone #: ###-####,, 4th floor. Per John, no inspection needed at this time.
BLD16-00147 BLD-Conference2/21/20172/21/20172/21/2017 1:20:49 PMPCANC
BLD16-04036 BLD-Final2/20/20172/21/20172/21/2017 1:20:13 PMPPASS
LOCK BOX CODE 1931. Phone #: ###-#### Inspection requested via web by Duane Seid. Ok for perm occ.
BLD16-00147 BLD-Conference2/17/20172/21/20172/21/2017 11:54:49 AMACANC
ADA door clearance conference Phone #: ###-#### Inspection requested via web by Mike Beeson
BLD15-04468 BLD-Conference2/19/20172/21/20172/21/2017 11:09:23 AMAPASS
Inspection of framing at concourse. Call Adam when on site. Thx akj Phone #: ###-#### Inspection requested via web by Adam Johnson. Remaining framing at concourse ok to cover. Also verified insulation at "diving board".
BLD16-01060 BLD-Framing/Rough-in2/17/20172/21/20172/21/2017 10:24:50 AMACANC
Roof Sheathing. Phone #: ###-#### Inspection requested via web by Michael West
BLD16-01059 BLD-Wall Bracing2/17/20172/21/20172/21/2017 10:24:30 AMAPART
Shear walls Units401-410 Phone #: ###-#### Inspection requested via web by Michael West. Interior shear walls for corrido walls at first floor. Nailing ok. Needs to install holdowns.
BLD16-02985 BLD-Framing/Rough-in2/17/20172/21/20172/21/2017 9:57:51 AMAPART
Phone #: ###-#### Inspection requested via web by Clint Wall. Provide attic access in living room. Ok to insualte.
BLD16-03116 BLD-Energy code compliance2/17/20172/21/20172/21/2017 9:31:43 AMAPASS
Phone #: ###-#### Inspection requested via web by Kyle Seick
BLD16-03116 BLD-Framing/Rough-in2/21/20172/21/20172/21/2017 9:31:33 AMAPASS
Phone #: ###-#### Inspection requested via web by Kyle Seick
BLD16-04302 BLD-Wall Bracing2/17/20172/21/20172/21/2017 9:16:23 AMANR
Shear inspection Phone #: ###-#### Inspection requested via web by Braxton Hansen. No city approved plans on site.
BLD16-00491 BLD-Final2/18/20172/21/20172/21/2017 9:07:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Clint Wall
BLD16-00491 DOC - Permit Finaled2/21/20172/21/20172/21/2017 9:07:19 AMPPASS
BLD16-02816 BLD-Conference2/17/20172/21/20172/21/2017 8:48:54 AMADONE
Please call ahead - Doug Phone #: ###-####