Inspections for the day of: Friday, February 21, 2020.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE20-00621 Final2/20/20202/21/20202/21/2020 2:55:05 PMPPASS
Please call Dakota @ ###-#### with any questions. Phone #: ###-#### Inspection requested via web by William Salts
Final ok
ELE20-00621 Permanent Service2/21/20202/21/20202/21/2020 2:33:36 PMPPASS
Please call Dakota @ ###-#### with any questions. Phone #: ###-#### Inspection requested via web by William Salts
p/s u/g rec ok
ELE20-00617 Final2/20/20202/21/20202/21/2020 2:25:38 PMPNR
Mark Phone #: ###-####
Needed permanent service inspection.
ELE20-00617 Permanent Service2/21/20202/21/20202/21/2020 2:19:24 PMPPASS
Mark Phone #: ###-####
Minimum work space shall be provided as per 110.26. Work bench present in front of panel location.
Ground rods shall be flush or recessed in ground as per 250.53(G). About 10" above grade at time of inspection.
At time of inspection grounding electrode installed and service entrance conductors being installed. All branch circuits still need to be installed in new main breaker panel.
p/s u/g rec ok
ELE19-04915 Final2/20/20202/21/20202/21/2020 1:32:38 PMPPASS
Phone #: ###-#### Inspection requested via web by Steven Ragan
Approved set of prints on site. Final ok
ELE20-00302 Final2/21/20202/21/20202/21/2020 12:48:19 PMAPASS
Please call Bruce @ ###-#### with any questions/concerns

Thank you ; have a lovely weekend! Phone #: ###-#### Inspection requested via web by JENNY EMEL
. Approved print on site.
Final ok
ELE20-00594 Electrical Rough-In2/20/20202/21/20202/21/2020 11:54:30 AMAPASS
Call when you get there 10th floor // Jose Phone #: ###-####
Few luminaires relocated and few receptacles relocated in floor. Rough in ok cover floor and ceiling.
ELE19-02646 Electrical Rough-In2/21/20202/21/20202/21/2020 11:35:17 AMAPASS
Requesting 11:00 am inspection. Wall sign install. Phone #: ###-#### Inspection requested via web by Ken Olsen
Disconnecting means located in ceiling space where drivers are located, Blade sign yet to install. Rough in ok.
ELE19-04444 Final2/20/20202/21/20202/21/2020 11:02:28 AMAFAIL
door code is 1974 Phone #: ###-#### Inspection requested via web by Darryn Coburn 210.52(A)(2)- Receptacle outlets shall be installed with in 6' each side of fireplace wall space. Such receptacles shall not be located in cabinets.
210.52(C)- Pantry counter top shall have receptacle outlets installed so that at no point on counter is more than 24" from a receptacle outlets.
250.94- A intersystem bond bar shall be installed to bond communication systems.
314.21- Drywall shall be repaired around RV receptacle box so gap around box does not exceed 1/8".
406.5(D)- Garage door opener receptacle shall have a cover installed so receptacle is flush with cover plate.
410.16(A)- Luminaires located in master clothes closet shall have totally enclosed lamps.
ELE20-00536 Final2/19/20202/21/20202/21/2020 10:34:15 AMAPASS
Service upgrade final Phone #: ###-#### Inspection requested via web by Lars Johnson Final ok
ELE20-00620 Temporary Service2/20/20202/21/20202/21/2020 9:04:38 AMAPASS
Phone #: ###-#### Inspection requested via web by Todd Hall t/s u/g n ok
ELE20-00618 Temporary Service2/20/20202/21/20202/21/2020 9:04:02 AMAPASS
Phone #: ###-#### Inspection requested via web by Todd Hall t/s u/g n ok
ELE20-00619 Temporary Service2/20/20202/21/20202/21/2020 9:03:36 AMAPASS
Phone #: ###-#### Inspection requested via web by Todd Hall t/s u/g n ok
ELE19-04915 Final2/20/20202/21/20202/20/2020 10:36:02 AMACANC
Phone #: ###-#### >> Inspection requested via web by Steven Ragan Inspection cancelled from web by: Steven Ragan