MEC18-00851
| Final | 2/22/2018 | 2/22/2018 | 2/22/2018 3:58:37 PM | P | PASS |
|
|
later pm please call Brett ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- furnace AC CO ok
|
MEC18-00851
| Pressure Test | 2/22/2018 | 2/22/2018 | 2/22/2018 3:57:59 PM | P | PASS |
|
|
later pm please call Brett ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- 5lb flue pass
|
MEC18-00843
| Final | 2/21/2018 | 2/22/2018 | 2/22/2018 3:26:06 PM | P | PASS |
|
|
installer Jesse ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace AC CO ok
|
MEC18-00845
| Rough-in | 2/21/2018 | 2/22/2018 | 2/22/2018 2:42:51 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Devony Bullard- need csst approved nail plates installed on gas line- dryer vent needs fixed and leveled- framing needs completed around ducting- b vent at roof needs clearance to combustibles
|
MEC18-00846
| Rough-in | 2/21/2018 | 2/22/2018 | 2/22/2018 2:41:33 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Devony Bullard- framking needs completed around ducting- insulation shield around b vent in garage- supply run hooked up main level bedroom- line set ran - left correction notice on window
|
MEC18-00857
| Rough-in | 2/22/2018 | 2/22/2018 | 2/22/2018 2:40:15 PM | P | FAIL |
|
|
This is a rough in and final inspection on pellet stove. Phone #: ###-#### Inspection requested via web by Jamee Shoecraft- need face plate remover to veryify clearances on pellet stove anfd fluing- need to reschedule for inspection or meet me their
|
MEC18-00845
| Pressure Test | 2/21/2018 | 2/22/2018 | 2/22/2018 2:30:54 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Devony Bullard- 20lb gas pass
|
MEC18-00846
| Pressure Test | 2/21/2018 | 2/22/2018 | 2/22/2018 2:30:38 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Devony Bullard- 20lb gas pass
|
MEC18-00827
| Pressure Test | 2/22/2018 | 2/22/2018 | 2/22/2018 1:20:03 PM | P | PASS |
|
|
Chuck ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- 20lb gas pass- will look at piping on roof when RTU is set
|
MEC17-05135
| Final | 2/21/2018 | 2/22/2018 | 2/22/2018 11:43:07 AM | A | PASS |
|
|
final - call mark Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok- was not able to get on roof due to snow to check RTU
|
MEC18-00850
| Rough-in | 2/21/2018 | 2/22/2018 | 2/22/2018 11:28:09 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Teresa Costello- R/I ok- need bath fan exhausted by final
|
MEC18-00766
| Rough-in | 2/21/2018 | 2/22/2018 | 2/22/2018 10:55:17 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace R/I ok
|
MEC18-00265
| Pressure Test | 2/21/2018 | 2/22/2018 | 2/22/2018 10:54:57 AM | A | FAIL |
|
|
If there are questions please contact Ryan J. ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann- guage at 51.5 psi
|
MEC18-00734
| Rough-in | 2/21/2018 | 2/22/2018 | 2/22/2018 10:43:58 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace R/I ok
|
MEC17-05384
| Final | 2/21/2018 | 2/22/2018 | 2/22/2018 10:33:55 AM | A | PASS |
|
|
gate code #9898 garage code: 6365 Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok
|
MEC17-02216
| Rough-in | 2/21/2018 | 2/22/2018 | 2/22/2018 10:25:17 AM | A | PART |
|
|
fire damper inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- went over fire/smoke damper locations with Bill V, Luke from TVR, Mike Jordan and GC- need to submit for new prints for locations of fire/smoke dampers to be deleted and show 4 only that need installed per our conference
|
MEC17-01493
| Mec-Aging Inspection | 2/22/2018 | 2/22/2018 | 2/22/2018 8:58:19 AM | | PEND |
|
|
contractor to schedule final per phone call
|
MEC17-01501
| Mec-Aging Inspection | 2/22/2018 | 2/22/2018 | 2/22/2018 8:37:00 AM | | PEND |
|
|
contractor will schedule final per phone call
|
MEC18-00360
| Final | 2/21/2018 | 2/22/2018 | 2/22/2018 8:35:13 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka
|
MEC18-00360
| Rough-in | 2/21/2018 | 2/22/2018 | 2/22/2018 8:35:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- R/I ok
|
MEC18-00601
| Rough-in | 2/21/2018 | 2/22/2018 | 2/22/2018 8:22:31 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jasmin Godina- fireplace R/I ok
|
MEC16-04723
| Mec-Aging Inspection | 2/22/2018 | 2/22/2018 | 2/22/2018 7:58:09 AM | | FAIL |
|
|
no inspections ever called in
|
MEC17-00226
| Mec-Aging Inspection | 2/22/2018 | 2/22/2018 | 2/22/2018 7:57:40 AM | | FAIL |
|
|
NEVER RECALLED IN FOR FINAL
|
MEC18-00525
| Conference | 2/20/2018 | 2/22/2018 | 2/21/2018 3:42:47 PM | A | CANC |
|
|
wit duct blast 930 am Phone #: ###-#### Inspection requested via web by dannyel chaloupka- will reschedule since duct blast tester not working per phone call
|