Inspections for the day of: Thursday, February 22, 2018.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-00824 Rough-in2/22/20182/22/20182/22/2018 4:14:20 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak
need approved manual j for inspection
MEC18-00824 Pressure Test2/22/20182/22/20182/22/2018 4:13:40 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak
20lb gas
MEC17-05696 Final2/21/20182/22/20182/22/2018 3:08:21 PMPPASS
Furnace is out back under a rug - let yourself in. Phone #: ###-#### Inspection requested via web by Kristin Dolan
MEC17-05500 Final2/22/20182/22/20182/22/2018 2:38:13 PMPFAIL
The final inspection is ready. Please let me know if there''s any issues? thank you so much, Heath Taylor T ; T Heating and Cooling Phone #: ###-#### Inspection requested via web by Heath Taylor
condencer needs to be minimume of 3' away from gas meter, vent on furnace is back graded in mechanical room
MEC18-00391 Final2/22/20182/22/20182/22/2018 2:01:16 PMPPASS
Please call Scott 30 minutes in advance for access at ###-#### and call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs
MEC18-00672 Rough-in2/22/20182/22/20182/22/2018 1:08:58 PMPPART
Please give us the first available afternoon inspection if possible. Contractor has insulation scheduled at 2 and we need inspection done before they can proceed. Please call ###-#### when you are on the way so we can meet you there. Thank you! Phone #: ###-#### Inspection requested via web by Dan McFate
dryer vents need to be 4 " diameter, wall needs furred out
MEC18-00628 Rough-in2/21/20182/22/20182/22/2018 11:20:42 AMAPASS
Phone #: ###-#### Inspection requested via web by Krista Boss
MEC18-00627 Rough-in2/21/20182/22/20182/22/2018 11:14:16 AMAPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves
MEC18-00409 Final2/15/20182/22/20182/22/2018 10:40:24 AMAPASS
Please call Brandi when in route to home ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd
MEC17-01336 Final2/21/20182/22/20182/22/2018 10:16:16 AMAFAIL
MIKE IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
gas regulator need water tight vent to ERU,
all kitchen equiptment on wheels needs tethers
MEC17-01500 Mec-Aging Inspection2/22/20182/22/20182/22/2018 9:28:13 AM CANC
MEC18-00841 Rough-in2/21/20182/22/20182/22/2018 8:11:24 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
MEC18-00841 Pressure Test2/21/20182/22/20182/22/2018 8:11:22 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves