Inspections for the day of: Thursday, February 23, 2006.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-00618 Final2/22/20062/23/20062/23/2006 4:04:54 PMPPASS
We installed a new 50 amp 4 wire range circuit with new receptacle. We also installed a new 20 amp 120 volt microwave circuit with a new receptacle.(#6020159barchas). Thanks!!!!! Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
ELE06-00232 Electrical Rough-In2/23/20062/23/20062/23/2006 3:17:47 PMPPART
This is for wall inspection, see Ryan at job site, or call 573.1871; Phone #: ###-#### Internet Inspection Request from: Daniel Gamboa
walls and hard lid ceiling ok
ELE06-00651 Rough-In Permanent Service2/23/20062/23/20062/23/2006 3:01:51 PMPPART
Verna; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
No R/I Yet on this job.
check outside grounding .ok for power.
P/S O/H R Ok
ELE06-00259 Electrical Rough-In2/23/20062/23/20062/23/2006 2:33:34 PMPFAIL
Colt; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
grounds are not made up in the boxes.
recessed cans have box overfill and temperature rateing exceeded for conductors.
ELE05-02922 Final2/23/20062/23/20062/23/2006 1:43:27 PMPPASS
Mark; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
no card
ELE05-03900 Rough-In Permanent Service2/22/20062/23/20062/23/2006 11:49:52 AMAFAIL
Lloyd -- for reinspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
#14 on a 20 A circuit.
secure all romex.
outer sheath to extend into box for water heater.
proper fitting on GEC.
ELE06-00491 Final2/17/20062/23/20062/23/2006 10:36:13 AMAPASS
We wired a new water heater. Thanks!!! Dan.#6010019.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
ELE06-00481 Final2/22/20062/23/20062/23/2006 10:36:00 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Joe Thomas
ELE05-03776 Final2/22/20062/23/20062/23/2006 9:43:54 AMAPASS
Please call Mike 1/2hr before for access ###-####. Thanks!; Phone #: ###-#### Internet Inspection Request from: Heather Packer
ELE05-04361 Final2/22/20062/23/20062/23/2006 9:29:37 AMAPASS
Aaron; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
ELE06-00309 Electrical Rough-In2/22/20062/23/20062/23/2006 9:05:41 AMAFAIL
please inspect the barn, thank you!; Phone #: ###-#### Internet Inspection Request from: William Zerfas
225.32 & 250.32
disconnect has more than the 15 in. of conduit permited by boise city in the building and no grounding electrode.