ELE06-00618
| Final | 2/22/2006 | 2/23/2006 | 2/23/2006 4:04:54 PM | P | PASS |
|
|
We installed a new 50 amp 4 wire range circuit with new receptacle. We also installed a new 20 amp 120 volt microwave circuit with a new receptacle.(#6020159barchas). Thanks!!!!! Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
|
ELE06-00232
| Electrical Rough-In | 2/23/2006 | 2/23/2006 | 2/23/2006 3:17:47 PM | P | PART |
|
|
This is for wall inspection, see Ryan at job site, or call 573.1871; Phone #: ###-#### Internet Inspection Request from: Daniel Gamboa walls and hard lid ceiling ok
|
ELE06-00651
| Rough-In Permanent Service | 2/23/2006 | 2/23/2006 | 2/23/2006 3:01:51 PM | P | PART |
|
|
Verna; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong No R/I Yet on this job. check outside grounding .ok for power. P/S O/H R Ok
|
ELE06-00259
| Electrical Rough-In | 2/23/2006 | 2/23/2006 | 2/23/2006 2:33:34 PM | P | FAIL |
|
|
Colt; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong grounds are not made up in the boxes. recessed cans have box overfill and temperature rateing exceeded for conductors.
|
ELE05-02922
| Final | 2/23/2006 | 2/23/2006 | 2/23/2006 1:43:27 PM | P | PASS |
|
|
Mark; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong no card
|
ELE05-03900
| Rough-In Permanent Service | 2/22/2006 | 2/23/2006 | 2/23/2006 11:49:52 AM | A | FAIL |
|
|
Lloyd -- for reinspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong #14 on a 20 A circuit. secure all romex. outer sheath to extend into box for water heater. proper fitting on GEC.
|
ELE06-00491
| Final | 2/17/2006 | 2/23/2006 | 2/23/2006 10:36:13 AM | A | PASS |
|
|
We wired a new water heater. Thanks!!! Dan.#6010019.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
|
ELE06-00481
| Final | 2/22/2006 | 2/23/2006 | 2/23/2006 10:36:00 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Joe Thomas
|
ELE05-03776
| Final | 2/22/2006 | 2/23/2006 | 2/23/2006 9:43:54 AM | A | PASS |
|
|
Please call Mike 1/2hr before for access ###-####. Thanks!; Phone #: ###-#### Internet Inspection Request from: Heather Packer
|
ELE05-04361
| Final | 2/22/2006 | 2/23/2006 | 2/23/2006 9:29:37 AM | A | PASS |
|
|
Aaron; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
|
ELE06-00309
| Electrical Rough-In | 2/22/2006 | 2/23/2006 | 2/23/2006 9:05:41 AM | A | FAIL |
|
|
please inspect the barn, thank you!; Phone #: ###-#### Internet Inspection Request from: William Zerfas 225.32 & 250.32 disconnect has more than the 15 in. of conduit permited by boise city in the building and no grounding electrode.
|