Inspections for the day of: Friday, February 23, 2007.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBill VanDegrift
TitlePLM-INSPECTOR
Phone #794-9372
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC05-00618 Final2/23/20072/23/20072/23/2007 4:21:04 PMPFAIL
1" to combustables on b-vent.remove expandable foam. shutoff valve required within 3' of water heater. called contractor.
MEC07-00585 Final2/22/20072/23/20072/23/2007 4:02:44 PMPPASS
PHONE# IS TO INSTALLER Phone #: ###-####
MEC07-00565 Final2/23/20072/23/20072/23/2007 3:10:43 PMPNR
PLM07-00490 Plumbing Rough-in2/23/20072/23/20072/23/2007 2:58:54 PMPPASS
terrell; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
MEC07-00546 Rough-in2/23/20072/23/20072/23/2007 2:58:28 PMPPASS
please do pressure also thanks travis. Phone #: ###-#### x6140 ri 20# ok
PLM06-04150 Final2/23/20072/23/20072/23/2007 2:06:58 PMPFAIL
Phone #: ###-#### pipe pan drain and t& p to approved location.
PLM06-04149 Final2/23/20072/23/20072/23/2007 2:06:15 PMPPASS
Phone #: ###-####
PLM07-00003 Final2/23/20072/23/20072/23/2007 1:36:45 PMPNH
bryan; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
MEC07-00559 Rough-in2/21/20072/23/20072/23/2007 11:41:41 AMPNH
JEANETTE; Phone #: ###-#### Internet Inspection Request from: Victoria Beall fresh concrete everywhere no access. resched. for monday am.
MEC06-03930 Final2/23/20072/23/20072/23/2007 11:18:21 AMPPASS
Phone #: ###-#### final ok
MEC06-03756 Final2/22/20072/23/20072/23/2007 11:03:52 AMAFAIL
Scheduled by a contractor via Hello! on 2/22/2007 at 8:34:36 AM. Contact: ###-####. permit gas piping and venting for water heater in addition. combustion air may not be supplied from the bath room. test gas piping. call for inspection.
MEC07-00132 Rough-in2/22/20072/23/20072/23/2007 10:40:08 AMAFAIL
Mech. Rough-in & Gas Pressure Test Re-Inspection. Access Domenic Paupolo Phone# ###-#### Phone #: ###-#### 1" min. clearance to combustables at b-vent/ ceiling above the water heaters. 20# test ok
PLM07-00498 Water and/or Sewer2/22/20072/23/20072/23/2007 9:58:34 AMAPART
Ready am Phone #: water service ok
PLM06-04180 Plumbing Rough-in2/22/20072/23/20072/23/2007 9:23:29 AMAFAIL
Call Joe for questions please Phone #: ###-#### tent all water lines in the attic prior to rough in approval. dwv and water systems tests are ok.
PLM07-00390 Plumbing Rough-in2/22/20072/23/20072/23/2007 9:04:32 AMAPASS
JOB CONTACT: RANDY REEVES #: ###-#### Phone #: ###-#### ri ok
PLM07-00493 Sprinkler (Final)2/22/20072/23/20072/23/2007 12:00:00 AMPCANC
Dan Caldwell ###-####