PLM18-00092
| Plumbing Rough-in | 2/22/2018 | 2/23/2018 | 2/26/2018 7:09:23 AM | P | PASS |
|
|
JOB # 51218 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM17-04446
| Plumbing Rough-in | 2/23/2018 | 2/23/2018 | 2/23/2018 2:32:11 PM | P | PASS |
|
|
Please accommodate a 3 o''clock inspection Phone #: ###-#### Inspection requested via web by David Scaggs
|
PLM18-00734
| Water and/or Sewer | 2/23/2018 | 2/23/2018 | 2/23/2018 1:40:05 PM | P | FAIL |
|
|
Jason Phone #: ###-####. 1. The water service may need to be 1-1/4. Check plans for total load. 2. Install a blue tracer wire. 3. Add an end of line cleanout at the upper terminal. 4. Remove the abs fitting from the pvc drain. 5. Put the system under test.
|
PLM18-00766
| Final | 2/22/2018 | 2/23/2018 | 2/23/2018 11:43:29 AM | A | FAIL |
|
|
Contact Name: Josh Wilson PLEASE CALL JOSH FOR DOOR LOCK CODE. Phone #: ###-#### Inspection requested via web by Melissa Kaae. 1. The indirect waste must have an air gap equal to 2x the diameter of the pipe. 2. The chemical feed at the mop sink must have it's own valve or a connection on the faucet that won't allow the faucet to be left on. 3. Pipe the grease trap per manufacturs instructions and plan specfications. 4. Add tempering valves on the public lavatories. Required with a change of tenant.
|
PLM18-00623
| Plumbing Rough-in | 2/22/2018 | 2/23/2018 | 2/23/2018 10:49:32 AM | A | PASS |
|
|
|
PLM17-02329
| Final | 2/19/2018 | 2/23/2018 | 2/23/2018 10:14:15 AM | A | PASS |
|
|
MASTER BATH TUB ; TOILET FINAL TRIM Phone #: ###-#### Inspection requested via web by Chris Field
|
PLM17-03541
| Plumbing Rough-in | 2/22/2018 | 2/23/2018 | 2/23/2018 9:57:36 AM | A | PART |
|
|
BRAD IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER. DWV rooms 120-121 ok to cover. South hall water complete
|
PLM17-04815
| Plumbing Rough-in | 2/23/2018 | 2/23/2018 | 2/23/2018 9:30:12 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Scaggs
|
PLM18-00711
| Final | 2/22/2018 | 2/23/2018 | 2/23/2018 9:05:33 AM | A | PART |
|
|
Please call Jimmy 30 min prior to arrival Phone #: ###-#### Inspection requested via web by Andrea Grigsby. sewer ok to cover
|
PLM17-04815
| Plumbing Rough-in | 2/22/2018 | 2/23/2018 | 2/23/2018 8:22:44 AM | P | CANC |
|
|
Please accommodate a 3 o''clock inspection Phone #: ###-#### >> Inspection requested via web by David Scaggs Inspection cancelled from web by: David Scaggs
|