Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM18-00092 Plumbing Rough-in2/22/20182/23/20182/26/2018 7:09:23 AMPPASS
JOB # 51218 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM17-04446 Plumbing Rough-in2/23/20182/23/20182/23/2018 2:32:11 PMPPASS
Please accommodate a 3 o''clock inspection Phone #: ###-#### Inspection requested via web by David Scaggs
PLM18-00734 Water and/or Sewer2/23/20182/23/20182/23/2018 1:40:05 PMPFAIL
Jason Phone #: ###-####.
1. The water service may need to be 1-1/4. Check plans for total load.
2. Install a blue tracer wire.
3. Add an end of line cleanout at the upper terminal.
4. Remove the abs fitting from the pvc drain.
5. Put the system under test.
PLM18-00766 Final2/22/20182/23/20182/23/2018 11:43:29 AMAFAIL
Contact Name: Josh Wilson
PLEASE CALL JOSH FOR DOOR LOCK CODE. Phone #: ###-#### Inspection requested via web by Melissa Kaae.
1. The indirect waste must have an air gap equal to 2x the diameter of the pipe.
2. The chemical feed at the mop sink must have it's own valve or a connection on the faucet that won't allow the faucet to be left on.
3. Pipe the grease trap per manufacturs instructions and plan specfications.
4. Add tempering valves on the public lavatories. Required with a change of tenant.
PLM18-00623 Plumbing Rough-in2/22/20182/23/20182/23/2018 10:49:32 AMAPASS
PLM17-02329 Final2/19/20182/23/20182/23/2018 10:14:15 AMAPASS
MASTER BATH TUB ; TOILET FINAL TRIM Phone #: ###-#### Inspection requested via web by Chris Field
PLM17-03541 Plumbing Rough-in2/22/20182/23/20182/23/2018 9:57:36 AMAPART
BRAD IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER.
DWV rooms 120-121 ok to cover.
South hall water complete
PLM17-04815 Plumbing Rough-in2/23/20182/23/20182/23/2018 9:30:12 AMPPASS
Phone #: ###-#### Inspection requested via web by David Scaggs
PLM18-00711 Final2/22/20182/23/20182/23/2018 9:05:33 AMAPART
Please call Jimmy 30 min prior to arrival Phone #: ###-#### Inspection requested via web by Andrea Grigsby. sewer ok to cover
PLM17-04815 Plumbing Rough-in2/22/20182/23/20182/23/2018 8:22:44 AMPCANC
Please accommodate a 3 o''clock inspection Phone #: ###-#### >> Inspection requested via web by David Scaggs Inspection cancelled from web by: David Scaggs