ELE09-01092
| ELE-Aging Inspection | 2/24/2010 | 2/24/2010 | 2/24/2010 3:59:44 PM | P | DONE |
|
|
bob this work is all complet pending your sign off. 301 no activity, see doc expire
|
ELE09-01092
| DOC - Permit Expired | 2/24/2010 | 2/24/2010 | 2/24/2010 3:59:07 PM | P | PASS |
|
|
bob this work is all complet pending your sign off. 301 no activity, ok to doc expire
|
ELE10-00234
| Final | 2/24/2010 | 2/24/2010 | 2/24/2010 3:56:32 PM | P | PASS |
|
|
Inspection requested from web by: TOM BICANDI Phone #: ###-#### called, ok to final, signed card, no esc this project
|
ELE10-00263
| Final | 2/24/2010 | 2/24/2010 | 2/24/2010 3:34:04 PM | P | PASS |
|
|
Greg Phone #: ###-#### corrections made, called, ok to final
|
ESC05-01650
| General Inspection | 2/24/2010 | 2/24/2010 | 2/24/2010 3:02:56 PM | P | PASS |
|
|
looked ok
|
ELE10-00062
| Final | 2/24/2010 | 2/24/2010 | 2/24/2010 2:16:05 PM | P | FAIL |
|
|
Contact: Paul Cushing before going Inspection requested from web by: Deb Gooden Phone #: ###-#### called, left correction notice, NEC 210.70(C) shall provide switched lighting outlet in pump hpuse, 110.22(A) shall identify disconnecting means with sufficient durability to withstand environment, 408.4 shall provide circuit directories, NOTE corrections shall be made within 5 working days or further action will be taken
|
ELE10-00062
| Electrical Rough-In | 2/24/2010 | 2/24/2010 | 2/24/2010 1:41:57 PM | P | PASS |
|
|
Contact: Paul Cushing before going Inspection requested from web by: Deb Gooden Phone #: ###-#### ok to cover u/g to sign only
|
ELE10-00130
| Final | 2/24/2010 | 2/24/2010 | 2/24/2010 1:31:16 PM | P | PASS |
|
|
keith Phone #: ###-#### ok to final, no esc this project
|
ELE10-00283
| Rough-In Permanent Service | 2/24/2010 | 2/24/2010 | 2/24/2010 12:55:29 PM | P | PASS |
|
|
keith Phone #: ###-#### ric ok, p/s u/g n ok, no esc this project
|
ELE10-00361
| Final | 2/23/2010 | 2/24/2010 | 2/24/2010 10:42:38 AM | A | PASS |
|
|
Please call me so i can meet you there. Thank You Dave Shifflett Inspection requested from web by: jason shifflett Phone #: ###-#### ok to final, no esc this project
|
ELE10-00361
| Permanent Service | 2/24/2010 | 2/24/2010 | 2/24/2010 10:10:13 AM | A | PASS |
|
|
Please call me so i can meet you there. Thank You Dave Shifflett Inspection requested from web by: jason shifflett Phone #: ###-#### p/s o/h rec ok, no esc this project
|
ELE09-02374
| Final | 2/23/2010 | 2/24/2010 | 2/24/2010 9:51:45 AM | A | PASS |
|
|
Inspection requested from web by: Scott Campbell Phone #: ###-#### ok to final, no esc this project
|
ELE10-00352
| Electrical Rough-In | 2/23/2010 | 2/24/2010 | 2/24/2010 9:17:23 AM | A | FAIL |
|
|
Jim Phone #: ###-#### called, left correction notice, NEC shall provide outlets and spacing in exposed walls and front receptacle, BCC shall change room count to 8 on elect permit, NOTE corrections shall be made within 5 working days or further action will be taken, no esc this project
|
ELE10-00349
| Temporary Service | 2/22/2010 | 2/24/2010 | 2/24/2010 9:13:52 AM | A | PASS |
|
|
Inspection requested from web by: Bob Glenn Phone #: ###-#### t/s u/g n ok, no esc this project
|
ELE09-02441
| Electrical Rough-In | 2/23/2010 | 2/24/2010 | 2/24/2010 9:12:51 AM | A | FAIL |
|
|
tony ###-#### called, left message, left correction notice, NEC 330.30(B) mc shall be secured within 12" of box, 300.4(A)(D) edge of holes and cable shall be 1 1/4" from edge of framing members,BCC shall not secure cable inside valley steel stud, shall terminate cable in box NOTE shall make corrections within 5 working days or further action will be taken
|