Inspections for the day of: Friday, February 24, 2012.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-00288 Final2/24/20122/24/20122/24/2012 3:12:46 PMPPASS
Phone #: ###-#### >> Inspection requested via web by mark hood
ELE12-00386 Temporary Service2/24/20122/24/20122/24/2012 3:12:28 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn
t/s u/g new ok
ELE12-00256 Final2/23/20122/24/20122/24/2012 2:27:15 PMAPASS
please call me at least 30 min. prior so I can get someone to let you in to the hospital. ###-#### Brian Phone #: ###-#### >> Inspection requested via web by Brian Hughes ok
ELE11-02797 Electrical Rough-In2/24/20122/24/20122/24/2012 2:02:35 PMPFAIL
This is an electrical grid inspection for areas of the Nordstrom Rack project. Contact on job is Tom Hackman. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery
both high and low voltage cables need proper suppot 300.11 wires from grid to structure, shall be ID for purpose note low voltage wiring supported off of grid, compactor not listed BCC, NEC 110.2&3,
shall be labeled and listed
ELE12-00376 Final2/23/20122/24/20122/24/2012 12:10:23 PMPFAIL
Temp power Phone #: ###-#### >> Inspection requested via web by Therrin Robertson needs address posted for lot , ID sticker at t/s clean dirt and leaves from t/s and request a t/s inspection not final called
ELE12-00383 Temporary Service2/24/20122/24/20122/24/2012 11:37:57 AMAFAIL
THANK YOU! THIS IS READY NOW Phone #: ###-#### >> Inspection requested via web by Bob Glenn called no address
ELE12-00370 Electrical Rough-In2/24/20122/24/20122/24/2012 10:35:01 AMPPASS
Underground Phone #: ###-#### >> Inspection requested via web by Stan Woodward ok
ELE12-00372 Rough-In Permanent Service2/24/20122/24/20122/24/2012 10:34:43 AMPPASS
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI
r/i p/s u/g new ok
ELE12-00375 Final2/23/20122/24/20122/24/2012 10:09:24 AMAPASS
Contact: Brian Gee - Please call before going, early as possible please Phone #: ###-#### >> Inspection requested via web by Deb Gooden
ELE12-00375 Permanent Service2/23/20122/24/20122/24/2012 10:09:12 AMAPASS
Contact: Brian Gee - Please call before going, early as possible please Phone #: ###-#### >> Inspection requested via web by Deb Gooden p/s o/h rec. ok
ELE12-00077 Electrical Rough-In2/23/20122/24/20122/24/2012 9:44:09 AMAPART
ceiling cover//Toby Phone #: ###-####
RME ceiling ok ----- low voltage contractor ceiling r/i failed correction posted on BLD11-02870 NEC 800.21&24, 300.11 support all low voltage cables above ceiling grid per codes noted . I explained this to the contractor 2 times now, once on 02-23-12, and today
ELE12-00192 Final2/23/20122/24/20122/24/2012 9:39:44 AMAPASS
Lock box #1040 Phone #: ###-#### >> Inspection requested via web by Lynn Proctor ok card signed
ESC09-00285 Aging Inspection2/24/20122/24/20122/24/2012 7:29:57 AM DONE
ok
ELE10-01250 ELE-Aging Inspection2/24/20122/24/20122/24/2012 7:03:16 AM CANC
ELE10-01175 ELE-Aging Inspection2/24/20122/24/20122/24/2012 7:03:02 AM CANC
ELE11-00916 ELE-Aging Inspection2/24/20122/24/20122/24/2012 7:02:51 AM CANC