Inspections for the day of: Friday, February 24, 2012.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02545 Final2/24/20122/24/20122/24/2012 4:36:02 PMPFAIL
Cal Phone #: ###-#### NEC 250.24 The grounded conductor (neutral) from an 4 wire branch circuit shall orginate from the grounding bar along with the equipment grounding conductor. NEC250.32(A) Buildings supplied by feeders or branch circuits shall have a grounding eletrode.NEC 250.56 A single electode consisting of a rod pipe, or plate that does not have a resistance of 25 ohms or less shall be argmented by an additional electrode NEC 300.4 Shall provide nail plates were NM cable or bored holes are less than 1 1/4 from edge of framing member
ELE11-00826 ELE-Aging Inspection2/24/20122/24/20122/24/2012 3:55:09 PM PASS
see final
ELE11-00826 Final2/24/20122/24/20122/24/2012 3:54:16 PMPPASS
final ok UL listed sign
ELE12-00385 Electrical Rough-In2/24/20122/24/20122/24/2012 3:30:23 PMPPASS
Jeff-please call 30 mins prior to inspection Phone #: ###-#### rough-in ok cover wall
ELE12-00384 Electrical Rough-In2/24/20122/24/20122/24/2012 3:29:43 PMPPASS
Jeff-please call 30 mins prior to inspection Phone #: ###-#### rough-in ok walls
ELE12-00382 Final2/24/20122/24/20122/24/2012 1:17:35 PMPPASS
A/C unit wtih service receptacle final ok
ELE12-00382 Electrical Rough-In2/24/20122/24/20122/24/2012 1:16:44 PMAPASS
Phone #: ###-#### >> Inspection requested via web by PAT MILLER rough-in ok
ELE11-01637 Electrical Rough-In2/24/20122/24/20122/24/2012 10:23:42 AMPPASS
Burt Phone #: ###-#### rough-in ok cover ceiling 2nd floor hallway
ELE12-00347 Electrical Rough-In2/23/20122/24/20122/24/2012 10:21:20 AMANH
Please call Harvey @ ###-#### 30 minutes before you will be there so he can unlock the building. Phone #: ###-#### >> Inspection requested via web by Celinda Winters
ELE12-00062 Electrical Rough-In2/23/20122/24/20122/24/2012 9:45:16 AMAPASS
Phone #: ###-#### >> Inspection requested via web by shane miller rough-in ok cover walls
ELE12-00057 Electrical Rough-In2/24/20122/24/20122/24/2012 9:21:06 AMAPASS
rough-in ok cover livingroom and up stairs area
ELE12-00057 Final2/23/20122/24/20122/24/2012 9:20:30 AMANR