BLD19-01148
| BLD-Aging Inspection | 2/24/2020 | 2/24/2020 | 2/25/2020 8:32:00 AM | | CANC |
|
|
|
BLD18-03760
| BLD-Aging Inspection | 2/24/2020 | 2/24/2020 | 2/25/2020 8:31:49 AM | | CANC |
|
|
|
BLD19-03252
| BLD-Wall cover | 2/23/2020 | 2/24/2020 | 2/24/2020 3:42:08 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Carl Funkrated separation walls only//blocking added at floor//insualtion needs to be R20 at exterior 2x8 rated walls//some insulation has fallen, would like to see as drywall is installed//
|
BLD19-03251
| BLD-Wall cover | 2/23/2020 | 2/24/2020 | 2/24/2020 3:41:54 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Carl Funk//rated separation walls only//blocking added at floor//insualtion needs to be R20 at exterior 2x8 rated walls//some insulation has fallen, would like to see as drywall is installed//
|
BLD19-03250
| BLD-Wall cover | 2/23/2020 | 2/24/2020 | 2/24/2020 3:41:32 PM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by Carl Funk//Still needs electrical approval for separation walls//
|
BLD19-03249
| BLD-Wall cover | 2/23/2020 | 2/24/2020 | 2/24/2020 3:41:02 PM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by Carl Funk//still needs Electrical approval for separation walls//
|
BLD20-00097
| BLD-Wall Bracing | 2/24/2020 | 2/24/2020 | 2/24/2020 3:08:15 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kelly Stover
|
BLD20-00098
| BLD-Wall Bracing | 2/24/2020 | 2/24/2020 | 2/24/2020 2:22:28 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kelly Stover//nailing ok// still need to add blocks//were working on them when i left//
|
BLD19-03229
| BLD-Wall cover | 2/23/2020 | 2/24/2020 | 2/24/2020 1:35:27 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Carl Funk// rated separation walls only//blocking added at floor//insualtion needs to be R20 at exterior 2x8 rated walls//some insulation has fallen, would like to see as drywall is installed//
|
BLD19-03248
| BLD-Wall cover | 2/23/2020 | 2/24/2020 | 2/24/2020 1:34:49 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Carl Funkrated separation walls only//blocking added at floor//insualtion needs to be R20 at exterior 2x8 rated walls//some insulation has fallen, would like to see as drywall is installed//
|
BLD19-03247
| BLD-Wall cover | 2/23/2020 | 2/24/2020 | 2/24/2020 1:34:28 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Carl Funkrated separation walls only//blocking added at floor//insualtion needs to be R20 at exterior 2x8 rated walls//some insulation has fallen, would like to see as drywall is installed//
|
BLD19-03253
| BLD-Wall cover | 2/23/2020 | 2/24/2020 | 2/24/2020 1:34:09 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Carl Funk rated separation walls only//blocking added at floor//insualtion needs to be R20 at exterior 2x8 rated walls//some insulation has fallen, would like to see as drywall is installed//
|
BLD19-02932
| BLD-Framing/Rough-in | 2/24/2020 | 2/24/2020 | 2/24/2020 12:49:39 PM | P | NR |
|
|
Graciela Phone #: ###-####//need to add studs at plate breaks near center door//need mechanical inspection//need electrical inspection//do not insulate until framing is approved//
|
MIS20-00043
| BLD-Conference | 2/10/2020 | 2/24/2020 | 2/24/2020 11:34:02 AM | A | DONE |
|
|
follow up..//2nd correction notice posted onsite//Blue Goat Roofing sign in front yard//will check back 5 days//
|
BLD20-00032
| BLD-Foundation | 2/21/2020 | 2/24/2020 | 2/24/2020 10:53:31 AM | A | PART |
|
|
flatwork // Max Phone #: ###-####//heaters were installed overnight,, no frost was observed in footing areas//talked with contractor and he will be pre-heating prior to pour//frost protection will need to be maintained
|
BLD19-00403
| BLD-Final | 2/20/2020 | 2/24/2020 | 2/24/2020 10:16:10 AM | A | FAIL |
|
|
Jack Phone #: ###-####//smoke detectors need added to bedrooms//smoke CO combo outside bedrooms and on first floor//they must be interconnected//
|
BLD19-03975
| BLD-Final | 2/18/2020 | 2/24/2020 | 2/24/2020 9:59:32 AM | A | DONE |
|
|
Phone #: ###-#### Inspection requested via web by Scott Smith
|
BLD19-03975
| DOC - Permit Finaled | 2/24/2020 | 2/24/2020 | 2/24/2020 9:59:22 AM | P | PASS |
|
|
new roof flashings installed//no access to back of duplex//roof appears to be installed within code requirements//
|
BLD19-03701
| BLD-Energy code compliance | 2/21/2020 | 2/24/2020 | 2/24/2020 9:35:52 AM | A | PASS |
|
|
Mark Phone #: ###-####//header added//insulation ok in walls//one attic area is R38 and needs to be R49--let contractor know prior to cover R49 needs to be installed//garage walls and ceiling insulated//second story of garage not insulated//will check deck and stairs at final-no handrails installed//
|
BLD20-00525
| BLD-Final | 2/19/2020 | 2/24/2020 | 2/24/2020 9:04:47 AM | A | DONE |
|
|
Phone #: ###-#### Inspection requested via web by Elizabeth Melendez
|
BLD20-00525
| DOC - Permit Finaled | 2/24/2020 | 2/24/2020 | 2/24/2020 9:04:36 AM | P | PASS |
|
|
no access to back of home//new roof flashings installed//roofing appears to be installed within code requirements//
|