Inspections for the day of: Monday, February 25, 2008.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-02092 Final2/25/20082/25/20082/25/2008 4:31:28 PMPPASS
ok to final
ELE07-03307 Electrical Rough-In2/22/20082/25/20082/25/2008 3:39:28 PMPPART
CONTACT: NEIL RAMSEY - ROUGH IN 5TH FLOOR DECK AREA PLEASE Phone #: ###-#### Internet Inspection Request from: Deb Gooden 5th floor deck ok to pour, reviewed several areas of job for progression, plans still being revised
ELE07-03784 Final2/25/20082/25/20082/25/2008 2:34:39 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Shaun Kirkman corrections made, signed occupancy card, ok to final
ELE07-02179 Electrical Rough-In2/25/20082/25/20082/25/2008 1:40:37 PMPFAIL
nathan-please call at least 30 mins prior to inspection Phone #: ###-#### met owner, left correction notice NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing member, 300.14 shall provide 6" free conductor length in box for splice connection point, 110.12(C) there shall be no broken parts (box knockouts), 110.3(B) listed equipment shall be instslled per manufacturer's instructions- no loose crimps, 334.30 nm cable shall be stapled or secured within 8" of box, 210.52(A)(2) shall provide receptacle in 2" wall space, BCC no violations shall be retained
ELE08-00452 Final2/25/20082/25/20082/25/2008 12:50:05 PMPPASS
pat Phone #: ###-#### ok to final
ELE08-00452 Electrical Rough-In2/25/20082/25/20082/25/2008 12:49:56 PMPPASS
pat Phone #: ###-#### ric ok
ELE06-00925 Final2/25/20082/25/20082/25/2008 10:44:31 AMAPASS
ok to final
ELE06-03501 Final2/25/20082/25/20082/25/2008 9:47:13 AMAPASS
ok to fnal
ELE08-00417 Conference2/20/20082/25/20082/25/2008 9:14:57 AMADONE
Todd Phone #: ###-#### met owner, talked about service change, getting illegal sub-panels either abandoned or converted to junction boxes, grounding, panel height, stapling, accessible junction boxes,
ELE08-00415 Electrical Rough-In2/20/20082/25/20082/25/2008 8:16:58 AMACANC
justin Phone #: ###-#### see conference
ELE08-00415 Conference2/25/20082/25/20082/25/2008 8:16:42 AMADONE
justin Phone #: ###-#### met contractor, explained that all permits shall be pulled, approved set of plans shall be on job, before work starts, service change will require bringing electrical up to code for areas being worked on