ELE11-02203
| ELE-Aging Inspection | 2/25/2013 | 2/25/2013 | 2/26/2013 2:48:58 PM | | DONE |
|
|
no call, still under construction
|
ELE13-00416
| Permanent Service | 2/25/2013 | 2/25/2013 | 2/25/2013 3:02:22 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dan Rohl p/s o/h rec ok
|
ELE13-00175
| Electrical Rough-In | 2/25/2013 | 2/25/2013 | 2/25/2013 2:06:04 PM | P | PASS |
|
|
Contact: Lyle Dean - underground inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden ok cover u/g into building
|
ELE13-00336
| Electrical Rough-In | 2/22/2013 | 2/25/2013 | 2/25/2013 1:55:04 PM | P | PASS |
|
|
Grounding Inspection, Steve Hook is contact. ###-####. thank you. Phone #: ###-#### >> Inspection requested via web by Debby Ellis south columns ok for grounding
|
ELE13-00414
| Electrical Rough-In | 2/25/2013 | 2/25/2013 | 2/25/2013 1:23:13 PM | P | PASS |
|
|
Contractor should be there all day.Thank you Phone #: ###-#### >> Inspection requested via web by George Pascua ri bath ok
|
ELE13-00304
| Final | 2/25/2013 | 2/25/2013 | 2/25/2013 12:40:34 PM | P | PASS |
|
|
added one new outlet up by front checkout area Phone #: ###-#### >> Inspection requested via web by Tim Dunlop ok final
|
ELE13-00269
| Electrical Rough-In | 2/25/2013 | 2/25/2013 | 2/25/2013 11:58:16 AM | P | PASS |
|
|
Underground only Phone #: ###-#### >> Inspection requested via web by William Andrews ok cover u/g house to garage only
|
ELE13-00407
| Electrical Rough-In | 2/25/2013 | 2/25/2013 | 2/25/2013 11:28:38 AM | A | PASS |
|
|
Western Tool work room. Retrofitting a few light fixtures from T12 to T8 in work room. Won''t be there till around 8:30am Phone #: ###-#### >> Inspection requested via web by Tim Dunlop ri ok
|
ELE13-00401
| Temporary Service | 2/23/2013 | 2/25/2013 | 2/25/2013 10:59:50 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Robert Murray t/s u/g n ok
|
ELE12-02735
| Electrical Rough-In | 2/22/2013 | 2/25/2013 | 2/25/2013 10:20:08 AM | A | PASS |
|
|
Bud on site. Ceiling inspection. Phone #: ###-#### >> Inspection requested via web by Clint Tate ok cover phase 1 ceiling only anop
|
ELE13-00399
| Rough-In Permanent Service | 2/22/2013 | 2/25/2013 | 2/25/2013 9:52:34 AM | A | PASS |
|
|
George Phone #: ###-#### ri ok, p/s o/h n (rec) ok
|
ELE13-00402
| Electrical Rough-In | 2/24/2013 | 2/25/2013 | 2/25/2013 9:17:55 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Nick Larson ri ok
|
ELE13-00406
| Rough-In Permanent Service | 2/24/2013 | 2/25/2013 | 2/25/2013 8:43:29 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey called, NEC 210.52(H) shall install receptacle in hall over 10' (garage entry), 334.30 shall secure nm cable within 12 of box (recessed cans)
|
ELE13-00170
| Final | 2/22/2013 | 2/25/2013 | 2/25/2013 8:03:56 AM | A | PASS |
|
|
0475 Phone #: ###-#### >> Inspection requested via web by kevin blackmon ok final
|
ELE13-00399
| Electrical Rough-In | 2/22/2013 | 2/25/2013 | 2/25/2013 12:00:00 AM | A | CANC |
|
|
Call for access Phone #: ###-#### >> Inspection requested via web by George Pascua
|