ELE14-00274
| Final | 2/25/2014 | 2/25/2014 | 2/25/2014 4:17:41 PM | P | FAIL |
|
|
Mike Phone #: ###-#### BCC-4-05-32-code violation not to be retained. Open light boxes devices,etc. remember spark rings in kitchen devices in tile NEC 314.20.
|
ELE14-00373
| Electrical Rough-In | 2/24/2014 | 2/25/2014 | 2/25/2014 3:39:06 PM | A | FAIL |
|
|
Addition to the house and sub panel Phone #: ###-#### >> Inspection requested via web by daniel bibikov NEC 334.30-romex or nm cable shall be secured supported within 12" of every box. 210.52-(D)- at least 1 receptacle shall be installed within 3 feet of outside edge of each basin in bath. 300.4(A)- NM cable shall be protected from physical damage. (nailplates) 314.16-boxes shall be of suffecient size to provide free space for all enclosed conductors.
|
ELE13-03460
| Final | 2/24/2014 | 2/25/2014 | 2/25/2014 3:00:52 PM | A | FAIL |
|
|
garage code 0713 enter Phone #: ###-#### >> Inspection requested via web by Emmet Bushman 408.4- circuit directory shall be completed. BCC-requires minimum of 50% of permenant lamps shall be high efficientcy type. or dimmable.
|
ELE14-00313
| Final | 2/25/2014 | 2/25/2014 | 2/25/2014 2:09:21 PM | P | CANC |
|
|
re energize service early pm please Phone #: ###-#### >> Inspection requested via web by shane vigil needed permenent service insp.
|
ELE14-00313
| Permanent Service | 2/25/2014 | 2/25/2014 | 2/25/2014 2:08:05 PM | P | PASS |
|
|
re energize service early pm please Phone #: ###-#### >> Inspection requested via web by shane vigil p/s o/h rec ok
|
ELE14-00442
| Electrical Rough-In | 2/25/2014 | 2/25/2014 | 2/25/2014 1:40:52 PM | P | PASS |
|
|
chris Phone #: ###-#### hvac ceiling work ok
|
ELE13-03399
| Final | 2/24/2014 | 2/25/2014 | 2/25/2014 1:36:11 PM | P | PASS |
|
|
Frank Phone #: ###-#### final ok
|