Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-00274 Final2/25/20142/25/20142/25/2014 4:17:41 PMPFAIL
Mike Phone #: ###-#### BCC-4-05-32-code violation not to be retained. Open light boxes devices,etc. remember spark rings in kitchen devices in tile NEC 314.20.
ELE14-00373 Electrical Rough-In2/24/20142/25/20142/25/2014 3:39:06 PMAFAIL
Addition to the house and sub panel Phone #: ###-#### >> Inspection requested via web by daniel bibikov NEC 334.30-romex or nm cable shall be secured supported within 12" of every box. 210.52-(D)- at least 1 receptacle shall be installed within 3 feet of outside edge of each basin in bath. 300.4(A)- NM cable shall be protected from physical damage. (nailplates) 314.16-boxes shall be of suffecient size to provide free space for all enclosed conductors.
ELE13-03460 Final2/24/20142/25/20142/25/2014 3:00:52 PMAFAIL
garage code 0713 enter Phone #: ###-#### >> Inspection requested via web by Emmet Bushman 408.4- circuit directory shall be completed. BCC-requires minimum of 50% of permenant lamps shall be high efficientcy type. or dimmable.
ELE14-00313 Final2/25/20142/25/20142/25/2014 2:09:21 PMPCANC
re energize service early pm please Phone #: ###-#### >> Inspection requested via web by shane vigil needed permenent service insp.
ELE14-00313 Permanent Service2/25/20142/25/20142/25/2014 2:08:05 PMPPASS
re energize service early pm please Phone #: ###-#### >> Inspection requested via web by shane vigil p/s o/h rec ok
ELE14-00442 Electrical Rough-In2/25/20142/25/20142/25/2014 1:40:52 PMPPASS
chris Phone #: ###-#### hvac ceiling work ok
ELE13-03399 Final2/24/20142/25/20142/25/2014 1:36:11 PMPPASS
Frank Phone #: ###-#### final ok