Inspections for the day of: Wednesday, February 25, 2015.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-00099 ELE-Aging Inspection2/25/20152/25/20152/26/2015 2:08:28 PM DONE
owner refusing to respond
ELE15-00484 Final2/24/20152/25/20152/25/2015 3:16:14 PMPPASS
Contact is Robert Gates. Please call 1/2 hour before arriving on site Phone #: ###-#### Inspection requested via web by Scott Campbell Final ok
ELE15-00484 Electrical Rough-In2/25/20152/25/20152/25/2015 2:22:28 PMPPASS
Contact is Robert Gates. Please call 1/2 hour before arriving on site Phone #: ###-#### Inspection requested via web by Scott Campbell Testing rack rough in ok
ELE15-00493 Final2/25/20152/25/20152/25/2015 2:17:20 PMPFAIL
Request key from office for access Phone #: ###-#### Inspection requested via web by jamie berg 110.7-Repair, remove, support and terminate all wiring under mobile home
ELE15-00493 Rough-In Permanent Service2/25/20152/25/20152/25/2015 1:44:51 PMPPASS
Request key from office for access Phone #: ###-#### Inspection requested via web by jamie berg Mobile home rough in ok p/s u/g rec ok
ELE15-00403 Conference2/25/20152/25/20152/25/2015 1:30:36 PMPDONE
Call ahead 20min for access - Richard Phone #: ###-#### Discussed code requirements for changing panel in garage, 200 amp to 200 amp with additional breaker spaces. Owner contractor now engineer from Arizona.
ELE15-00486 Rough-In Permanent Service2/24/20152/25/20152/25/2015 1:15:51 PMAPASS
call first, ###-#### Phone #: ###-#### Inspection requested via web by PAT MILLER Access for final individual at 7008 Selway. Old panel location turned into junction point in garage. Service rough in ok. p/s o/h rec ok
ELE15-00490 Temporary Service2/24/20152/25/20152/25/2015 12:53:25 PMPPASS
Inspection requested via web by Greg Traudt t/s u/g n ok
ELE14-03260 Final2/25/20152/25/20152/25/2015 11:31:35 AMPFAIL
210.4- 3 phase multiwire branch circuit pulled on single phase service.
100 Multiwire branch circuits- All ungrounded conductor shall have voltage between them.
ELE15-00462 Permanent Service2/24/20152/25/20152/25/2015 11:16:17 AMAFAIL
Inside panel changed out. Metering remained the same. Any questions, please call Steve at ###-####. Thanks Phone #: ###-#### Inspection requested via web by Barbara Szurgot 250.53(D)(2)- If used as grounding electrode, underground water pipe shall be supplemented by an additional grounding electrode.
250.92(B)- (B) Method of Bonding at the Service. Bonding jumpers meeting the requirements of this article shall be used around impaired connections, such as reducing washers or oversized, concentric, or eccentric knockouts. Standard locknuts or bushings shall not be the only means for the bonding required by this section but shall be permitted to be installed to make a mechanical connection of the raceway(s).
ELE15-00393 Final2/23/20152/25/20152/25/2015 10:13:15 AMACANC
Samantha Phone #: ###-#### Needed rough in inspection.
ELE15-00393 Electrical Rough-In2/25/20152/25/20152/25/2015 10:13:05 AMPPASS
Samantha Phone #: ###-#### Service permit exists ele15-00307 requested for final had no access final on one of garage trips. Garage rough in ok cover
ELE14-03437 Final2/24/20152/25/20152/25/2015 10:01:08 AMAPASS
Mike Phone #: ###-#### Final ok
ELE15-00396 Final2/24/20152/25/20152/25/2015 9:37:15 AMPPASS
Please call Rick 1/2 hour before inspection for access Phone #: ###-#### Inspection requested via web by Rick Beckman Final ok
ELE14-02213 Electrical Rough-In2/24/20152/25/20152/25/2015 8:46:24 AMAPASS
Mike Phone #: ###-#### 8 Fixtures damaged during shipping,4 x-ray and 4 corridor. Contractor will be on site in future with ladder. Corridor, x-ray rooms, and front reception areas grid rough in ok cover
ELE15-00474 Temporary Service2/24/20152/25/20152/25/2015 7:56:48 AMAPASS
Phone #: ###-#### Inspection requested via web by Robert Schroder t/s u/g n ok
ELE15-00485 Electrical Rough-In2/24/20152/25/20152/24/2015 4:13:48 PMAPASS
Pulled the separate permit Phone #: ###-#### Inspection requested via web by Brad Baker Check for show room receptacles. Wall rough in ok cover