ELE15-00492
| Rough-In Permanent Service | 2/25/2015 | 2/25/2015 | 2/26/2015 12:52:16 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks Kitchen OK to cover, PS, OH, RC, OK
|
ELE15-00450
| Temporary Service | 2/24/2015 | 2/25/2015 | 2/25/2015 3:03:15 PM | P | PART |
|
|
brian Phone #: ###-#### inspection on meter to get power, still need to see wiring to trailers. TS, UG, N, OK
|
ELE09-02259
| ELE-Aging Inspection | 2/25/2015 | 2/25/2015 | 2/25/2015 2:43:29 PM | | DONE |
|
|
left message
|
ELE10-01957
| ELE-Aging Inspection | 2/25/2015 | 2/25/2015 | 2/25/2015 2:40:05 PM | | DONE |
|
|
Spoke to owner, still under construction, but close
|
ELE14-03285
| Electrical Rough-In | 2/25/2015 | 2/25/2015 | 2/25/2015 2:38:11 PM | P | PASS |
|
|
Eric Phone #: ###-#### corrections made, RI OK
|
ELE14-03458
| Final | 2/25/2015 | 2/25/2015 | 2/25/2015 2:25:05 PM | P | CANC |
|
|
ROUGH-IN ON GARAGE Phone #: ###-#### Inspection requested via web by John VanZandt Wrong inspection, needed RI not final
|
ELE14-03458
| Electrical Rough-In | 2/25/2015 | 2/25/2015 | 2/25/2015 2:24:23 PM | P | PASS |
|
|
ROUGH-IN ON GARAGE Phone #: ###-#### Inspection requested via web by John VanZandt
OK to cover Garage,
For service to garage, 250.32 (B) Ungrounded Systems. The equipment of an ungrounded separately derived system shall be grounded and bonded as specified in 250.30(B)(1) through (B)(3). (1) Grounding Electrode Conductor. A grounding electrode conductor, sized in accordance with 250.66 for the largest derived ungrounded conductor (s) or set of derived ungrounded conductors, shall be used to connect the metal enclosures of the derived system to the grounding electrode as specified in 250.30(A)(5) or (6), as applicable. This connection shall be made at any point on the separately derived system from the source to the first system disconnecting means. If the source is located outside the building or structure supplied, a grounding electrode connection shall be made in compliance with 250.30(C).
|
ELE15-00488
| Final | 2/24/2015 | 2/25/2015 | 2/25/2015 1:36:07 PM | P | FAIL |
|
|
Wood spa on upper deck. Phone #: ###-#### Inspection requested via web by Kotton Corder 680.22 (3) Other Receptacles, Location. Other receptacles shall be not less than 1.83 m (6 ft) from the inside walls of a pool. 680.22. B (3) Existing Installations. Existing luminaires and lighting outlets located less than 1.5 m (5 ft) measured horizontally from the inside walls of a pool shall be not less than 1.5 m (5 ft) above the surface of the maximum water level, shall be rigidly attached to the existing structure, and shall be protected by a ground-fault circuit interrupter. 680.26 (7) Fixed Metal Parts. All fixed metal parts shall be bonded including, but not limited to, metal-sheathed cables and raceways, metal piping, metal awnings, metal fences, and metal door and window frames 680.26(C) Pool Water. Where none of the bonded parts is in direct connection with the pool water, the pool water shall be in direct contact with an approved corrosion-resistant conductive surface that exposes not less than 5800 mm2 (9 in.2) of surface area to the pool water at all times. The conductive surface shall be located where it is not exposed to physical damage or dislodgement during usual pool activities, and it shall be bonded in accordance with 680.26(B)
|
ELE15-00487
| Electrical Rough-In | 2/25/2015 | 2/25/2015 | 2/25/2015 12:33:52 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt ri OK to cover, kitchen, master bath, laundry, new panel, misc basement areas, smokes
|
ELE14-03542
| Final | 2/24/2015 | 2/25/2015 | 2/25/2015 10:54:00 AM | A | PASS |
|
|
Call ###-#### for access Phone #: ###-#### Inspection requested via web by Heath Thomas Final OK
|
ELE14-03540
| Final | 2/24/2015 | 2/25/2015 | 2/25/2015 10:14:45 AM | A | PASS |
|
|
Call ###-#### for access Phone #: ###-#### Inspection requested via web by Heath Thomas FInal OK
|
ELE14-03296
| Final | 2/24/2015 | 2/25/2015 | 2/25/2015 9:35:18 AM | A | PASS |
|
|
Garage code 3283 thank you Phone #: ###-#### Inspection requested via web by daniel bibikovs corrections made, Final OK
|
ELE14-03383
| Final | 2/25/2015 | 2/25/2015 | 2/25/2015 9:16:19 AM | A | PASS |
|
|
Please call Scott ###-#### 1/2 prior for access to the home. Phone #: ###-#### Inspection requested via web by Buster Bowen FInal oK
|
ELE15-00069
| Final | 2/25/2015 | 2/25/2015 | 2/25/2015 9:06:17 AM | A | CANC |
|
|
Rough in on office and bathroom remodel Phone #: ###-#### Inspection requested via web by daniel bibikov needed ri
|
ELE15-00069
| Electrical Rough-In | 2/25/2015 | 2/25/2015 | 2/25/2015 9:05:56 AM | P | PASS |
|
|
Rough in on office and bathroom remodel Phone #: ###-#### Inspection requested via web by daniel bibikov Called daniel to immedeiately remove grounded receptacles from ungrounded circuit. RI OK to cover
|