Inspections for the day of: Tuesday, February 25, 2020.
Number of inspections: 27
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-00691 Rough-in2/25/20202/25/20202/25/2020 3:34:12 PMPFAIL
Ready for inspection Phone #: ###-#### Inspection requested via web by Oleg Chervak- need city approved man j onsite for inspection none found
MEC20-00691 Pressure Test2/25/20202/25/20202/25/2020 3:32:05 PMPPASS
Bad gauge, please reinspect Phone #: ###-#### Inspection requested via web by Oleg Chervak- 5lb flue pass
MEC20-00711 Final2/25/20202/25/20202/25/2020 3:19:04 PMPFAIL
Call Bobbi ###-#### in route to inspection Phone #: ###-#### Inspection requested via web by Justin Osterhout- package unit on roof ok- need co detectors installed- need electrical issued for new disconnect and breakers installed- homeowner noted breaker keeps tripping- send pics of co detectors
MEC20-00775 Final2/25/20202/25/20202/25/2020 3:02:05 PMPPASS
Please call Dave on your way and inspect later PM - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co locking caps ok
MEC19-04221 Final2/25/20202/25/20202/25/2020 2:00:40 PMPFAIL
garage code #4646 Phone #: ###-#### Inspection requested via web by Debbie Marino-
1- need locking caps on a/c service port
2- need to support lineset outside
3- need to insulate outside air in garage
4- need to seal/tape exposed insulation on each side of filter access door
MEC20-00050 Final2/25/20202/25/20202/25/2020 1:46:06 PMPPASS
Front door is open Phone #: ###-#### Inspection requested via web by JOSE DUARTE- final ok
MEC19-05813 Final2/25/20202/25/20202/25/2020 1:37:14 PMPPASS
Front door is open Phone #: ###-#### Inspection requested via web by JOSE DUARTE- final ok
MEC20-00052 Final2/25/20202/25/20202/25/2020 1:33:21 PMPFAIL
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- need approved man j onsite- need air balance report onsite- duct blast test passed
MEC20-00053 Final2/25/20202/25/20202/25/2020 1:28:36 PMPPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- final ok
MEC20-00051 Final2/25/20202/25/20202/25/2020 1:24:20 PMPPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- final ok
MEC19-05377 Final2/24/20202/25/20202/25/2020 1:00:09 PMPPASS
AC: 2020 Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok
MEC19-05222 Final2/25/20202/25/20202/25/2020 12:39:50 PMPPASS
GARI ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace final ok- mantel installed
MEC20-00740 Final2/24/20202/25/20202/25/2020 12:32:33 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co lockings ok
MEC19-04998 Rough-in2/25/20202/25/20202/25/2020 12:16:31 PMPPART
Shane Phone #: ###-####- R/I 2 ehaust, dryer duct and return duct above floor ok- recall in for R/I when crawl and dryer duct installed- ok to cover
MEC20-00679 Final2/25/20202/25/20202/25/2020 11:11:54 AMAPASS
final ok
MEC20-00769 Final2/24/20202/25/20202/25/2020 11:04:07 AMAPASS
Phone #: ###-#### Inspection requested via web by Denise Colin- furnace a/c coil co locking caps ok
MEC20-00769 Pressure Test2/24/20202/25/20202/25/2020 11:03:31 AMAPASS
Phone #: ###-#### Inspection requested via web by Denise Colin- 5lb flue pass
MEC20-00454 Pressure Test2/21/20202/25/20202/25/2020 10:38:32 AMAFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass tagged meter location- flue not under test
MEC20-00454 Rough-in2/21/20202/25/20202/25/2020 10:38:03 AMANR
Phone #: ###-#### Inspection requested via web by Randy Hart- still installing and waiting on material
MEC20-00762 Rough-in2/24/20202/25/20202/25/2020 10:37:38 AMAFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart- flue at 2.5 psi- metal to plastic connection on exhaust fans need sealed prior to outer insulation- insulation shield in garage needs to go all the way to roof pitch and 1" clearance to insulation shield- left notice on range duct
MEC20-00762 Pressure Test2/24/20202/25/20202/25/2020 10:36:02 AMAFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass tagged meter location- flue at 2.5 psi
MEC20-00590 Final2/24/20202/25/20202/25/2020 9:57:06 AMAPASS
I am requesting as a courtesy for the customer that he get a morning inspection. Due to us not leaving a ladder on Friday for inspector. Customer has already waited all day on Friday for inspection. Phone #: ###-#### Inspection requested via web by Devry King- electric furnace in attic ok
MEC20-00766 Final2/24/20202/25/20202/25/2020 9:34:11 AMAPASS
Please contact homeowner with an ETA. If you can''t reach him please contact Tania with Easy Heating and Air ###-####. Thank You! Phone #: ###-#### Inspection requested via web by Kelly Martin- furnace onlyin attic co ok
MEC20-00609 Final2/24/20202/25/20202/25/2020 9:18:49 AMAPASS
Final to close 208.921.9290
No RM on site - contact ###-#### or ###-#### to gain access Phone #: ###-#### Inspection requested via web by RM Mechanical- registers relocation ok- final ok- no card onsite
MEC20-00609 Card not on site to sign2/25/20202/25/20202/25/2020 9:17:43 AMAPASS
Final to close 208.921.9290
No RM on site - contact ###-#### or ###-#### to gain access Phone #: ###-#### Inspection requested via web by RM Mechanical- no card onsite
MEC20-00704 Final2/25/20202/25/20202/25/2020 8:32:36 AMANH
Phone #: ###-#### Inspection requested via web by Aaron Alandt- no one home- no access- left notice front door- reschedule
MEC19-03498 Mec-Aging Inspection2/25/20202/25/20202/25/2020 7:43:34 AM FAIL
contractor needs to schedule inspection no activity since permit issued- permit will expire next aging if no activity