ELE97-03227
| INSP - Electrical Rough-In | 2/25/1998 | 2/26/1998 | 2/26/1998 12:00:00 AM | A | PASS |
|
|
PERM SERV OK
|
ELE98-00025
| INSP - Electrical Rough-In | 2/25/1998 | 2/26/1998 | 2/26/1998 12:00:00 AM | A | PART |
|
|
02/26/98 315 - ed pager ###-#### ok low voltage wiring corrected by AEI ceiling
|
ELE98-00111
| INSP - Final | 2/25/1998 | 2/26/1998 | 2/26/1998 12:00:00 AM | A | PASS |
|
|
02/26/98 315 - dan ###-#### re insp ok cor. made
|
ELE98-00587
| INSP - Final | 2/24/1998 | 2/26/1998 | 2/26/1998 12:00:00 AM | A | PART |
|
|
02/26/98 315 - elevator/state liquor disp/ gowen plaza #3/ ###-#### ok no 14 r/i
|
ELE98-00599
| INSP - Electrical Rough-In | 2/25/1998 | 2/26/1998 | 2/26/1998 12:00:00 AM | A | PASS |
|
|
02/26/98 315 - R/I AND PERM---BOB ###-#### 15rms 1a/c 200a
|
ELE98-00602
| INSP - Electrical Rough-In | 2/26/1998 | 2/26/1998 | 2/26/1998 12:00:00 AM | P | PASS |
|
|
02/26/98 315 - ###-#### REMODEL OF FIVE ROOMS ok 4rms res. rem. also did a conference with B&B on 2/25/98
|
ELE98-00214
| INSP - Electrical Rough-In | 2/26/1998 | 2/26/1998 | 2/26/1998 12:00:00 AM | P | FAIL |
|
|
02/26/98 315 - THIS IS FOR A GARAGE--DOOR IS OPEN--###-#### LEE cor. posted B.C.C. needs to complete r/i, 336-18 support romex at boxes, 336-30 (b) use approved cable type NM B not old type NM
|
ELE98-00546
| INSP - Electrical Rough-In | 2/26/1998 | 2/26/1998 | 2/26/1998 12:00:00 AM | P | PASS |
|
|
02/26/98 315 - PERM SERV--KAREN ###-#### ok 200a
|
ELE98-00574
| INSP - Final | 2/26/1998 | 2/26/1998 | 2/26/1998 12:00:00 AM | P | FAIL |
|
|
02/26/98 315 - jack has no number will leave unlocked cor. posted 310-15 note #8 derate for 50% conduit fill, 110-3(b) use manufactures breakers only, 250-23 isolate grds and neutrals at sub pane house, 250-81 terminate grd within 5ft of where water pipe enters
|