ELE17-04364
| Electrical Rough-In | 2/26/2018 | 2/26/2018 | 2/26/2018 3:32:48 PM | P | PART |
|
|
please call 30 min. prior Phone #: ###-#### Inspection requested via web by John Edwards Owner moving in inspection to check existing portion of residence. 210.8- Receptacle outets located with in 6' of a sink shall have GFCI protection. Near kitchen sink. 406.4(D)- Grounding type receptacles installed on ungrounded circuits shall be GFCI protected. Unable to locate GFCI devices for existing grounding type receptacles.
|
ELE17-02585
| Final | 2/23/2018 | 2/26/2018 | 2/26/2018 2:17:57 PM | A | PASS |
|
|
Install 2 pay stations signs, 2 sidewalk signs,1 park sign on Idaho street and 1 park sign on Main street. At Capitol and Main Parking Garage. ALL PRIMARY POWER BY OTHERS Phone #: ###-#### Inspection requested via web by Ken Olsen Final ok
|
ELE17-02585
| Electrical Rough-In | 2/23/2018 | 2/26/2018 | 2/26/2018 2:17:20 PM | A | PASS |
|
|
Install 2 pay stations signs, 2 sidewalk signs,1 park sign on Idaho street and 1 park sign on Main street. At Capitol and Main Parking Garage. ALL PRIMARY POWER BY OTHERS Phone #: ###-#### Inspection requested via web by Ken Olsen Listing and disconnecting means confirmed. Rough in ok.
|
ELE17-01961
| Final | 2/23/2018 | 2/26/2018 | 2/26/2018 1:49:55 PM | A | PASS |
|
|
Install 2 pay stations signs, 2 sidewalk signs,1 park sign on Idaho street and 1 park sign on Main street. At 9th and Main Parking Garage. ALL PRIMARY POWER BY OTHERS Phone #: ###-#### Inspection requested via web by Ken Olsen Final ok
|
ELE17-01961
| Electrical Rough-In | 2/23/2018 | 2/26/2018 | 2/26/2018 1:49:25 PM | A | PASS |
|
|
Install 2 pay stations signs, 2 sidewalk signs,1 park sign on Idaho street and 1 park sign on Main street. ALL PRIMARY POWER BY OTHERS Phone #: ###-#### Inspection requested via web by Ken Olsen Listing and disconnecting means confirmed. Rough in ok
|
ELE18-00410
| Final | 2/23/2018 | 2/26/2018 | 2/26/2018 1:17:06 PM | A | PASS |
|
|
Will not be on site space should be open by 8 am Phone #: ###-#### Inspection requested via web by robert feller Final ok
|
ELE17-04027
| Final | 2/25/2018 | 2/26/2018 | 2/26/2018 12:46:08 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Steve Craig BCC 4-05-23 It shall be unlawful to cover any wiring or equipment prior to inspection. Kitchen grid installed prior to inspection. Kitchen appliances installed no access to devices. 210.8- All GFCI devices shall be located in a readily accessible location. 210.8(B)- All kitchen receptacles shall have GFCI protection, 1 pole and multi pole receptacles. 300.15- All wiring shall terminate in a box. Sign conduits, above north door, mezz wiring in floor. open box in basement, above grid.
|
ELE16-03931
| Final | 2/23/2018 | 2/26/2018 | 2/26/2018 10:09:07 AM | A | PART |
|
|
Units 310,410, 510, 610 ; 710 Courtyard 3rd level and Rooftop Contact Bob Mott Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Roof top and level 3 patio on core and shell permit, made notes on that permit. 310, 410, 414, 510, 610, 710 signed off in office. TCO OK
|
ELE16-03932
| Final | 2/23/2018 | 2/26/2018 | 2/26/2018 10:06:55 AM | A | PART |
|
|
Courtyard 3rd level and Rooftop Contact Bob Mott Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Roof top on core and shell permit ELE16-03933. Made notes on that permit.
|
ELE16-00580
| Final | 2/26/2018 | 2/26/2018 | 2/26/2018 10:05:44 AM | P | PART |
|
|
Roof strapping complete, Check heat tape EPD and service receptacle for mini splits garage. Work clearences 217.
|
ELE16-03933
| Final | 2/26/2018 | 2/26/2018 | 2/26/2018 10:03:34 AM | P | PART |
|
|
Parking garage island has been removed with no plans to relocate. will do with island located at mezz. level. Court yard heat tape OK, Window trim under outdoor receptacle gasket level 3 patios, Check heat tape EPD at garage mini split locations and service receptacles. AFCI posted.
|
ELE17-04364
| Electrical Rough-In | 2/23/2018 | 2/26/2018 | 2/26/2018 8:41:13 AM | A | NH |
|
|
Phone #: ###-#### Inspection requested via web by John Edwards House occupied contractor to call in when accessible
|