Inspections for the day of: Monday, February 26, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-04364 Electrical Rough-In2/26/20182/26/20182/26/2018 3:32:48 PMPPART
please call 30 min. prior Phone #: ###-#### Inspection requested via web by John Edwards
Owner moving in inspection to check existing portion of residence.
210.8- Receptacle outets located with in 6' of a sink shall have GFCI protection. Near kitchen sink.
406.4(D)- Grounding type receptacles installed on ungrounded circuits shall be GFCI protected. Unable to locate GFCI devices for existing grounding type receptacles.
ELE17-02585 Final2/23/20182/26/20182/26/2018 2:17:57 PMAPASS
Install 2 pay stations signs, 2 sidewalk signs,1 park sign on Idaho street and 1 park sign on Main street. At Capitol and Main Parking Garage. ALL PRIMARY POWER BY OTHERS Phone #: ###-#### Inspection requested via web by Ken Olsen Final ok
ELE17-02585 Electrical Rough-In2/23/20182/26/20182/26/2018 2:17:20 PMAPASS
Install 2 pay stations signs, 2 sidewalk signs,1 park sign on Idaho street and 1 park sign on Main street. At Capitol and Main Parking Garage. ALL PRIMARY POWER BY OTHERS Phone #: ###-#### Inspection requested via web by Ken Olsen Listing and disconnecting means confirmed. Rough in ok.
ELE17-01961 Final2/23/20182/26/20182/26/2018 1:49:55 PMAPASS
Install 2 pay stations signs, 2 sidewalk signs,1 park sign on Idaho street and 1 park sign on Main street. At 9th and Main Parking Garage. ALL PRIMARY POWER BY OTHERS Phone #: ###-####
Inspection requested via web by Ken Olsen Final ok
ELE17-01961 Electrical Rough-In2/23/20182/26/20182/26/2018 1:49:25 PMAPASS
Install 2 pay stations signs, 2 sidewalk signs,1 park sign on Idaho street and 1 park sign on Main street. ALL PRIMARY POWER BY OTHERS Phone #: ###-#### Inspection requested via web by Ken Olsen Listing and disconnecting means confirmed. Rough in ok
ELE18-00410 Final2/23/20182/26/20182/26/2018 1:17:06 PMAPASS
Will not be on site space should be open by 8 am Phone #: ###-#### Inspection requested via web by robert feller
Final ok
ELE17-04027 Final2/25/20182/26/20182/26/2018 12:46:08 PMAFAIL
Phone #: ###-#### Inspection requested via web by Steve Craig
BCC 4-05-23 It shall be unlawful to cover any wiring or equipment prior to inspection. Kitchen grid installed prior to inspection. Kitchen appliances installed no access to devices.
210.8- All GFCI devices shall be located in a readily accessible location.
210.8(B)- All kitchen receptacles shall have GFCI protection, 1 pole and multi pole receptacles.
300.15- All wiring shall terminate in a box. Sign conduits, above north door, mezz wiring in floor. open box in basement, above grid.
ELE16-03931 Final2/23/20182/26/20182/26/2018 10:09:07 AMAPART
Units 310,410, 510, 610 ; 710
Courtyard 3rd level and Rooftop
Contact Bob Mott
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek
Roof top and level 3 patio on core and shell permit, made notes on that permit.
310, 410, 414, 510, 610, 710 signed off in office. TCO OK
ELE16-03932 Final2/23/20182/26/20182/26/2018 10:06:55 AMAPART
Courtyard 3rd level and Rooftop
Contact Bob Mott
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek
Roof top on core and shell permit ELE16-03933. Made notes on that permit.
ELE16-00580 Final2/26/20182/26/20182/26/2018 10:05:44 AMPPART
Roof strapping complete, Check heat tape EPD and service receptacle for mini splits garage. Work clearences 217.
ELE16-03933 Final2/26/20182/26/20182/26/2018 10:03:34 AMPPART
Parking garage island has been removed with no plans to relocate. will do with island located at mezz. level. Court yard heat tape OK, Window trim under outdoor receptacle gasket level 3 patios, Check heat tape EPD at garage mini split locations and service receptacles. AFCI posted.
ELE17-04364 Electrical Rough-In2/23/20182/26/20182/26/2018 8:41:13 AMANH
Phone #: ###-#### Inspection requested via web by John Edwards House occupied contractor to call in when accessible