ELE06-02266
| Final | 2/27/2008 | 2/27/2008 | 2/27/2008 4:03:58 PM | P | PASS |
|
|
ok to final
|
ELE06-00408
| Final | 2/27/2008 | 2/27/2008 | 2/27/2008 3:58:07 PM | P | FAIL |
|
|
james Phone #: ###-#### called, left correction notice, NEC 408.4 shall provide circuit directory that is clear, concise, and explanatory for each circuit, 408.38 panelboard shall be dead-front, cover installed
|
ELE08-00389
| Permanent Service | 2/27/2008 | 2/27/2008 | 2/27/2008 2:31:04 PM | P | PASS |
|
|
brian Phone #: ###-#### p/s o/h rec ok
|
ELE08-00355
| Final | 2/26/2008 | 2/27/2008 | 2/27/2008 1:40:22 PM | P | PASS |
|
|
danny - please call ahead so i can meet you Phone #: ###-#### ok to final
|
ELE07-02179
| Electrical Rough-In | 2/27/2008 | 2/27/2008 | 2/27/2008 12:46:34 PM | P | PASS |
|
|
nathan Phone #: ###-#### corrections made, called,, ric ok
|
ELE07-04087
| Final | 2/26/2008 | 2/27/2008 | 2/27/2008 10:55:31 AM | A | PASS |
|
|
don Phone #: ###-#### corrections, ok to final
|
ELE07-03429
| Electrical Rough-In | 2/26/2008 | 2/27/2008 | 2/27/2008 10:40:16 AM | A | FAIL |
|
|
Jay Phone #: ###-#### or Travis at ###-#### called, left correction notice, NEC 334.30 nm cable shall be stapled within 12" of boxes, cabinets and every 4 1/2', 314.17(C) nm cable sheath shall extend minimum 1/4" inside box, and be secured within 8" of single gang boxes, 300.4(A)(1) edge of bored holes shall be 1 1/4" from face of framing members or protected by steel plate, 210.52(E) at least one receptacle shall be installed at front of dwelling and be accessible at grade level, BCC all make-up shall be done and boxes installed, tub is listed
|
ELE08-00349
| Permanent Service | 2/26/2008 | 2/27/2008 | 2/27/2008 9:54:44 AM | A | PASS |
|
|
Job site contact: Gene ###-#### Phone #: ###-#### Internet Inspection Request from: Tracy Robertson corrections made, p/s u/g n ok, 5 meters required
|
ELE08-00317
| Final | 2/26/2008 | 2/27/2008 | 2/27/2008 9:12:29 AM | A | FAIL |
|
|
DAVE CALL PRIOR TO HEADING TO SITE Phone #: ###-#### Internet Inspection Request from: Sean DeLacy met contractor, left correction notice, BCC no violations shall be retained, NEC 300.11(A) raceways shall be secured in place, and not on grid, 330.30(B) mc cable shall be secured within 12" of box,358.30(A) emt shall be secured within 3' of box, 408.4 circuit directory shall be clear, concise, complete, and explanatory for each circuit, 725.3(B) abandoned class2,3, pltc cables shall be removed, 725.8 cass1,2,3 cables shall be installed in a workman like manner and be supported
|
ELE08-00415
| Electrical Rough-In | 2/26/2008 | 2/27/2008 | 2/27/2008 8:33:36 AM | A | PASS |
|
|
justin - kitchen area Phone #: ###-#### ric ok kitchen area
|
ELE08-00294
| Final | 2/27/2008 | 2/27/2008 | 2/27/2008 8:12:53 AM | A | PASS |
|
|
this to final the work I did another permit will be placed by someone else to finish the project Phone #: ###-#### Internet Inspection Request from: Don Lustig ok to final, signed structural card
|