ELE19-00468
| Permanent Service | 2/27/2019 | 2/27/2019 | 2/27/2019 2:22:11 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Winters LLC p/s o/h rec ok
|
ELE19-00477
| Electrical Rough-In | 2/27/2019 | 2/27/2019 | 2/27/2019 1:52:17 PM | P | CANC |
|
|
Call Luke to meet you there. ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan No repairs needed here, just service reconnect.
|
ELE19-00490
| Electrical Rough-In | 2/27/2019 | 2/27/2019 | 2/27/2019 1:50:55 PM | P | PASS |
|
|
Call Luke to meet you there. ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Only wiring damaged is located in "B" unit in bedroom closet. Replaced switch leg and water heater circuits. Rest of drywall removed to check wiring. No improvements made, if improvements are made rest will be required to be brought up to current code. Unit "B" rough in ok cover
|
ELE19-00273
| Electrical Rough-In | 2/26/2019 | 2/27/2019 | 2/27/2019 12:56:19 PM | P | PASS |
|
|
Kitchen rewire insp Phone #: ###-#### Inspection requested via web by John VanZandt Kitchen rough in ok cover
|
ELE19-00240
| Electrical Rough-In | 2/26/2019 | 2/27/2019 | 2/27/2019 11:25:52 AM | A | PASS |
|
|
Garage rough Insp Phone #: ###-#### Inspection requested via web by John VanZandt Panel hung and stuffed but grounding electrode not complete and feeders not done, No concrete encased electrode found. Rest rough in ok cover
|
ELE18-04169
| Final | 2/26/2019 | 2/27/2019 | 2/27/2019 10:55:36 AM | A | FAIL |
|
|
*7285 Phone #: ###-#### Inspection requested via web by Ben Archibald 110.3- Furnace field connection if on interior of casing shall be in junction box provide as per manufacturers instructions. Interior wiring shall be 105 degree celcius rated. 314.16- Boses shall have adaquate free conductor space for all conductors and devices installed. Island receptacle boxes 8 cubic inch with 11.25 cubic inches of conductor installed. 356.30- LFNC shall be secured with in 12" of an enclosure. Strap AC whip.
|
ELE19-00683
| Electrical Rough-In | 2/26/2019 | 2/27/2019 | 2/27/2019 9:41:43 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Icon Electric Rough in ok cover
|
ELE19-00683
| Permanent Service | 2/27/2019 | 2/27/2019 | 2/27/2019 9:41:28 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Icon Electric We will add inspection this one time. It is not our job to fix your missed requests. p/s u/g n ok
|
ELE18-04855
| Final | 2/26/2019 | 2/27/2019 | 2/27/2019 9:32:06 AM | A | PASS |
|
|
garage code 2468 Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
|