BLD20-00487
| BLD-Other | 2/27/2020 | 2/27/2020 | 2/27/2020 4:19:34 PM | P | NR |
|
|
Hazen Phone #: ###-####//need to insulate for mechanical approval//get mechanical inspection and call for re-inspection//
|
BLD19-02667
| BLD-Wall Bracing | 2/26/2020 | 2/27/2020 | 2/27/2020 3:23:22 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by James Jackson
|
BLD19-04515
| BLD-Footing | 2/26/2020 | 2/27/2020 | 2/27/2020 2:47:40 PM | P | PART |
|
|
Chris Phone #: ###-####//front setbacks tight--will need to remeasure at wall inspection to verify//
|
BLD20-00104
| BLD-Framing/Rough-in | 2/26/2020 | 2/27/2020 | 2/27/2020 2:46:58 PM | P | PASS |
|
|
Please call 30 minutes in advance Phone #: ###-#### Inspection requested via web by Chase Cheverton//ok to insulate//add ledger screws to ceiling ledger//
|
BLD19-02407
| BLD-Wall Bracing | 2/26/2020 | 2/27/2020 | 2/27/2020 1:35:58 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by James Jackson//ok--adding hot dipped galvanized nails while onsite//
|
BLD19-03992
| BLD-Framing/Rough-in | 2/26/2020 | 2/27/2020 | 2/27/2020 1:22:19 PM | P | PASS |
|
|
Willie Phone #: ###-####//ok to insulate//add stud under two ply beam//add h2.5 at porch cover//need 2 layers 5/8 for 1 hour eave//
|
BLD19-04576
| BLD-Foundation | 2/26/2020 | 2/27/2020 | 2/27/2020 11:19:07 AM | A | PASS |
|
|
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru
|
BLD19-00646
| BLD-Concrete | 2/26/2020 | 2/27/2020 | 2/27/2020 10:10:55 AM | A | PASS |
|
|
Steve Phone #: ###-####//rebar for CMU wall//ok when top 4 bar installed per drawings//
|
BLD19-04360
| BLD-Framing/Rough-in | 2/25/2020 | 2/27/2020 | 2/27/2020 9:51:12 AM | A | NR |
|
|
Josh Phone #: ###-####//correction notice issued//need to lower egress window//fire block concealed space//air seal//plan mod for changes and beam calcs and address cut beam at end//need mechanical permit//
|
MIS19-00124
| MIS-Aging Inspection | 2/27/2020 | 2/27/2020 | 2/27/2020 8:51:01 AM | | DONE |
|
|
|
MIS19-00124
| DOC - Permit Finaled | 2/27/2020 | 2/27/2020 | 2/27/2020 8:50:52 AM | P | PASS |
|
|
permit was issued and finaled//BLD19-01673
|
BLD18-03781
| BLD-Aging Inspection | 2/27/2020 | 2/27/2020 | 2/27/2020 8:49:42 AM | | DONE |
|
|
Expires: 04/13/20
|
BLD19-04058
| BLD-Aging Inspection | 2/27/2020 | 2/27/2020 | 2/27/2020 8:48:59 AM | | CANC |
|
|
|
MIS19-00127
| MIS-Aging Inspection | 2/27/2020 | 2/27/2020 | 2/27/2020 8:48:12 AM | | DONE |
|
|
|
MIS19-00127
| DOC - Permit Finaled | 2/27/2020 | 2/27/2020 | 2/27/2020 8:48:03 AM | P | PASS |
|
|
see previous entry
|
BLD20-00325
| BLD-Framing/Rough-in | 2/26/2020 | 2/27/2020 | 2/27/2020 8:35:11 AM | A | CANC |
|
|
Jay Walters will be the onsite contact Phone #: ###-#### Inspection requested via web by BRS Permitting//. No work needed to strengthen the existing roof structure per engineer’s roof evaluation.//framing inspection not required//
|