Inspections for the day of: Tuesday, February 28, 2017.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01942 ELE-Aging Inspection2/28/20172/28/20173/1/2017 10:38:30 AM DONE
Left message with Tom. He will look into it and call in when ready.
ELE17-00506 Temporary Service2/28/20172/28/20172/28/2017 2:30:48 PMPPASS
READY NOW Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE17-00475 Final2/28/20172/28/20172/28/2017 2:20:50 PMPPASS
Altenergy Contact Info ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller Final ok
ELE17-00013 Final2/28/20172/28/20172/28/2017 2:20:21 PMPFAIL
garage code 1001 Phone #: ###-#### Inspection requested via web by Charles Davis 210.8 A 3 All outdoor receps shall be GFCi protected. ( recep by panel) 110.3 B Listed equipment Shall be installed per man specs. (front WP recep.) 406.9 B 1 Outdoor receps shall be weather resistant.( front WP recep) 334.12 NM cable shall not be exposed. ( romex above range hood)
ELE16-04162 Final2/28/20172/28/20172/28/2017 2:16:21 PMPFAIL
garage code 1001 Phone #: ###-#### Inspection requested via web by Charles Davis 110.3 B Listed equipment shall be installed per man. specs. Up bath GFCI double protected. Up hall recep and Laundry room lighting Dead.
ELE16-03147 Electrical Rough-In2/27/20172/28/20172/28/2017 12:55:51 PMPPASS
Partial Bathrooms - Shannon is the contact his cell no is ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates Bath hard lid only ok to cover
ELE16-03279 Final2/28/20172/28/20172/28/2017 12:07:16 PMPPASS
All inspections done on ELE16-03665 FInal ok
ELE16-03524 Final2/27/20172/28/20172/28/2017 12:04:10 PMAFAIL
2010 code Phone #: ###-#### Inspection requested via web by danny perrine
110.3 B Listed equipment shall be installed per manufacturers instructions.( Back storage room of shop. Single pole upside down. Main Garage 3way locked out. Shop 3way. 210.52 C Counter tops in pantries shall have receps installed so that no point measured along wall line is mor than 24in from recep.
ELE17-00095 Temporary Service2/28/20172/28/20172/28/2017 10:44:26 AMAPASS
Please contact Ryan ###-#### with questions Phone #: ###-#### Inspection requested via web by Tracy Robertson t/s u/g n ok
ELE17-00385 Final2/27/20172/28/20172/28/2017 10:44:03 AMAPASS
We will call first thing in the morning to schedulea time to meet you onsite. Phone #: ###-#### Inspection requested via web by Matthew Dunay final ok
ELE17-00301 Conference2/28/20172/28/20172/28/2017 10:43:35 AMADONE
Please contact Ryan ###-#### on-site Phone #: ###-#### Inspection requested via web by Tracy Robertson Talked about recep spacing in kitchen and usable wall space. No receps required on pantry or kitchen wall.
ELE16-02993 Electrical Rough-In2/27/20172/28/20172/28/2017 8:46:36 AMAPASS
Ryan Phone #: ###-#### Partial cover NE corner soffit. Missing 1 can. All other soffits ok to cover