Inspections for the day of: Wednesday, February 28, 2018.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-00766 Rough-In Permanent Service2/27/20182/28/20182/28/2018 2:26:35 PMPPASS
Phone #: ###-#### Inspection requested via web by Neal Rumsey p/s u/g n ok. Fireplace installed and wired.
ELE17-03764 Final2/28/20182/28/20182/28/2018 1:58:08 PMPCANC
Mucho Phone #: ###-#### Unable to check anything. House was masked off inside and covers were missing for painting.
ELE18-00685 Permanent Service2/22/20182/28/20182/28/2018 1:38:50 PMPPASS
There will be guys there working. If you have any questions please feel free to contact Luke ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clay Morgan p/s o/h rec ok. Existing service relocated.
ELE18-00032 Electrical Rough-In2/28/20182/28/20182/28/2018 1:27:48 PMPCANC
Pls call Bryce (Foreman) @ ###-#### or Barry (Electrician) @ ###-#### one hr prior to arrival or if you have any questions. Thank you. Inspection requested via web by Rob Maes Should have been a final. I added a final inspection.
ELE18-00032 Final2/28/20182/28/20182/28/2018 1:27:19 PMPPASS
Ok final. I cancelled other inspection as it was a RI. RI was already done.
ELE17-04315 Final2/28/20182/28/20182/28/2018 1:00:43 PMPPASS
Phone #: ###-#### Inspection requested via web by Kevin Heideman Ok final. Disc for garage located on W side.
ELE17-04314 Final2/28/20182/28/20182/28/2018 1:00:17 PMPPASS
Phone #: ###-#### Inspection requested via web by Kevin Heideman Ok final. Disc for garage located W side.
ELE18-00768 Rough-In Permanent Service2/28/20182/28/20182/28/2018 12:47:24 PMPPASS
Phone #: ###-#### Inspection requested via web by steve sellers p/s o/h n ok. Weatherhead is about 35" away from 2nd floor window.
ELE17-03683 Electrical Rough-In2/28/20182/28/20182/28/2018 12:24:07 PMPPASS
Phone #: ###-#### Inspection requested via web by Kevin Perez Ok cover. Disc to be on NW side of garage.
ELE18-00770 Final2/28/20182/28/20182/28/2018 11:56:17 AMPPASS
Please ask for Jake at front desk. Phone #: ###-#### Inspection requested via web by Dustin Kuester Ok final. Installed recepts in room by stairs at entry, and 1 in ceiling for retractable cord in room on N side main level.
ELE18-00482 Final2/28/20182/28/20182/28/2018 11:31:10 AMPPASS
Please call Lee 30 min prior to arrival Phone #: ###-#### Inspection requested via web by Andrea Grigsby Ok final.
ELE17-03951 Electrical Rough-In2/27/20182/28/20182/28/2018 11:02:15 AMAPASS
Contact: Clayton Pennington underground inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden Ok cover 3/4" conduit on SE side of property. Conduits used for HVAC and power for outlets in classrooms.
ELE17-01905 Final2/27/20182/28/20182/28/2018 11:01:03 AMAPASS
I will be on-site by 9am Phone #: ###-#### Inspection requested via web by Sean Patton Ok final.
ELE18-00741 Electrical Rough-In2/28/20182/28/20182/28/2018 10:16:24 AMAPASS
inspection for walls only in tenant area on 3rd floor next to elevator, door should be unlocked Phone #: ###-#### Inspection requested via web by steve sellers Ok cover 1 room upon entry, and 3 rooms S side and bath.
ELE18-00262 Electrical Rough-In2/27/20182/28/20182/28/2018 9:48:11 AMAPASS
Wall cover.. Von is the onsite contact Phone #: ###-#### Inspection requested via web by Buster Bowen Ok cover Sections B,C,D interior walls. Sections C and D exterior walls left.
ELE18-00764 Electrical Rough-In2/27/20182/28/20182/28/2018 9:46:54 AMAPASS
Phone #: ###-#### Inspection requested via web by John VanZandt Ok cover garage.
ELE18-00745 Rough-In Permanent Service2/27/20182/28/20182/28/2018 9:18:27 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk p/s u/g n ok. Fireplace installed and wired.
ELE18-00729 Rough-In Permanent Service2/27/20182/28/20182/28/2018 8:54:51 AMAPASS
Phone #: ###-#### Inspection requested via web by kevin blackmon p/s u/g n ok. Fireplace installed and wired.
ELE17-04005 Final2/27/20182/28/20182/28/2018 8:44:48 AMAPASS
Phone #: ###-#### Inspection requested via web by Chase Sessions Ok final. All GEC landed under pressure connector behind access cover to parking lot lights.
ELE17-02957 Final2/27/20182/28/20182/28/2018 8:43:48 AMAPASS
Phone #: ###-#### Inspection requested via web by Chase Sessions Ok final. All lights installed.