Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD15-03528 BLD-Final2/27/20162/29/20162/29/2016 4:22:41 PMPPASS
Phone #: ###-#### Inspection requested via web by sheila fawley
BLD15-03528 DOC - Permit Finaled2/29/20162/29/20162/29/2016 4:22:18 PMPPASS
BLD15-04138 BLD-Conference2/29/20162/29/20162/29/2016 4:18:01 PMPPART
Troy is doing the fire final this morning. Phone #: ###-#### Inspection requested via web by Miles Hash. OK for Temp
BLD15-03245 BLD-Final2/27/20162/29/20162/29/2016 3:56:30 PMPPASS
Phone #: ###-#### Inspection requested via web by sheila fawley
BLD15-03245 DOC - Permit Finaled2/29/20162/29/20162/29/2016 3:56:02 PMPPASS
BLD16-00261 BLD-Framing/Rough-in2/26/20162/29/20162/29/2016 3:49:11 PMPNR
David Phone #: ###-####
BLD15-04457 BLD-Conference2/29/20162/29/20162/29/2016 3:35:09 PMPDONE
Ed Phone #: ###-####
BLD15-03794 BLD-Wall Bracing2/26/20162/29/20162/29/2016 3:05:09 PMAPART
Phone #: ###-#### Inspection requested via web by Weston Wagner. Missing hold down
BLD15-03796 BLD-Conference2/26/20162/29/20162/29/2016 3:04:10 PMPDONE
Phone #: ###-#### Inspection requested via web by Weston Wagner
BLD15-03796 BLD-Energy code compliance2/29/20162/29/20162/29/2016 3:03:47 PMPPASS
Phone #: ###-#### Inspection requested via web by Weston Wagner
BLD15-03792 BLD-Framing/Rough-in2/26/20162/29/20162/29/2016 2:59:27 PMPFAIL
Phone #: ###-#### Inspection requested via web by Weston Wagner. Truss bracing A4, B4 girder naling, Point load support for patio beam and front deck beam and beam at the bottom of the stairs, missing header over door into master bath and into 2nd bedroom in the bearing wall.
BLD15-03805 BLD-Framing/Rough-in2/29/20162/29/20162/29/2016 2:09:34 PMPPASS
Plans on site Inspection requested via web by Erby Gonzales
BLD16-00060 BLD-Foundation2/29/20162/29/20162/29/2016 1:03:35 PMPPASS
1:00 Phone #: ###-#### Inspection requested via web by tony L
BLD16-00059 BLD-Foundation2/29/20162/29/20162/29/2016 1:02:41 PMPPASS
1:00 Phone #: ###-#### Inspection requested via web by tony L
BLD15-04112 BLD-Foundation2/29/20162/29/20162/29/2016 1:00:48 PMPPASS
1:00 Phone #: ###-#### Inspection requested via web by tony L
BLD15-03800 BLD-Wall Bracing2/26/20162/29/20162/29/2016 11:02:39 AMAPART
Phone #: ###-#### Inspection requested via web by Weston Wagner. Hold downs
BLD15-03396 BLD-Wall Bracing2/26/20162/29/20162/29/2016 10:41:16 AMAPASS
Shear // Tony Phone #: ###-####
BLD15-03394 BLD-Framing/Rough-in2/26/20162/29/20162/29/2016 10:29:43 AMAPASS
Clint Phone #: ###-####
BLD15-03892 BLD-Energy code compliance2/29/20162/29/20162/29/2016 10:07:29 AMAPASS
Inspection requested via web by Erby Gonzales
BLD15-03894 BLD-Energy code compliance2/29/20162/29/20162/29/2016 10:06:52 AMAPASS
Inspection requested via web by Erby Gonzales
BLD15-03875 BLD-Framing/Rough-in2/26/20162/29/20162/29/2016 9:50:52 AMAPASS
Phone #: ###-#### Inspection requested via web by Kyle Buzzell
BLD16-00546 BLD-Conference2/28/20162/29/20162/29/2016 8:48:46 AMADONE
As early as possible Phone #: 2087036272 >> Inspection requested via mobile web by Chris homeyer
BLD16-00546 BLD-Footing2/29/20162/29/20162/29/2016 8:48:37 AMPPASS
As early as possible Phone #: 2087036272 >> Inspection requested via mobile web by Chris homeyer
BLD13-00252 BLD-Aging Inspection2/29/20162/29/20162/29/2016 8:25:18 AM PEND
BLD15-03568 BLD-Energy code compliance2/29/20162/29/20162/29/2016 6:50:32 AMACANC
>> Inspection requested via web by Erby Gonzales Inspection cancelled from web by: Erby Gonzales