ELE04-01654
| Final | 1/31/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | NH |
|
|
Phone #: call 1/2 hr ahead tim ###-#### Internet Inspection Request from: Heather Packer
called and the contact person was headed out of town. 2/3/2005 9:42:02 AM
|
ELE05-00348
| Rough-In Permanent Service | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | FAIL |
|
|
john ###-####
boxes overfilled
nail plate
required receps between fireplace and fixed panel of slider
broken box
parallel protection 2/3/2005 9:39:30 AM
|
ELE04-03385
| Final | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | FAIL |
|
|
jay; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
counter recep required 2/3/2005 10:58:00 AM
|
ELE04-03386
| Final | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | FAIL |
|
|
jay; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
closet light location 2/3/2005 10:58:20 AM
|
ELE05-00332
| Electrical Rough-In | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | PASS |
|
|
calvin; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
ELE05-00348
| Permanent Service | 2/3/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | PASS |
|
|
P/S U/G N Ok
|
ELE03-01832
| Final | 2/3/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | CANC |
|
|
conf 2/3/2005 10:00:16 AM
|
ELE05-00360
| Electrical Rough-In | 2/3/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | NH |
|
|
###-#### - steve Note: please call 1/2 hr prior to inspection
called no access he will reschedual 2/3/2005 1:22:21 PM
|
ELE04-03851
| Electrical Rough-In | 2/3/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | NR |
|
|
CONTACT: TONY HOLT; Phone #: ###-#### Internet Inspection Request from: Deb McCoy
|
ELE04-03847
| Electrical Rough-In | 2/3/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | PART |
|
|
6th floor ceilings and eleviator lobby walls
|
ELE04-03394
| Rough-In Permanent Service | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | PART |
|
|
Approval for cover - ceiling and walls. Please inspect late afternoon.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs
walls and ceiling on north side of buildiing ok 2/3/2005 2:56:13 PM
|
ELE05-00298
| Rough-In Permanent Service | 2/3/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | PASS |
|
|
PAT, THIS IS READY NOW. THE CONCRETE ENCASED ELECTRODE IS IN THE LAUNDRY AREA.THANKS BILL Internet Inspection Request from: Bob Glenn
P/S U/G N Ok
R/I Ok 2/3/2005 4:01:37 PM
|
ELE03-00203
| Final | 2/3/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 2/3/2005 at 9:39:01 AM. Contact: ###-####.
GFCI's in kitchen and garage
required receps to serve counter and light for man door
2/3/2005 4:20:13 PM
|
ELE04-00301
| Electrical Rough-In | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | PASS |
|
|
CONTACT: LYLE DEAN; Phone #: ###-#### Internet Inspection Request from: Deb McCoy
|