ELE04-03856
| Final | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | PASS |
|
|
glenn- ###-#### ok to final 2/3/2005 9:07:00 AM
|
ELE05-00338
| Permanent Service | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 2/2/2005 at 11:32:36 AM. Contact: ###-####. 110.26 (F) there shall be no foreign pipes above the dedicated equipment space. 2/3/2005 10:26:54 AM
|
ELE05-00343
| Permanent Service | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | CANC |
|
|
Lindy; Phone #: ###-#### Internet Inspection Request from: Jan Rice Talked to owner and told them that elect set a time in the pm and will co-ordinate access to house. will cancel this request. 2/2/2005 3:16:39 PM
|
ELE04-00421
| Temporary Service | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 2/2/2005 at 1:48:32 PM. Contact: ###-####. corrections made. t/s o/h n ok 2/3/2005 9:22:01 AM
|
ELE05-00335
| Electrical Rough-In | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | FAIL |
|
|
Dennis; Phone #: ###-#### Internet Inspection Request from: Jan Rice Bcc all wires shall be made up in boxes,314.17 nm cable shall be stapled within 8" of box. 2/3/2005 8:49:51 AM
|
ELE05-00353
| Electrical Rough-In | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | A | CANC |
|
|
Shaun; Phone #: ###-#### Internet Inspection Request from: Jan Rice Called contractor, No job id, no plans, no address, told him to recall when ready so we are at right place. 2/3/2005 8:09:07 AM
|
ELE04-01991
| Final | 2/3/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 2/3/2005 at 7:58:15 AM. Contact: ###-####. 350.30(A) liquid-tite shall be supported within 3' of box, 358.30 emt shall be strapped within 3' of box, 358.26 there shall not be more than 360 degree in conduit bends, 110.12(A) unused openings shall be closed in panel, 408.4 Panels shall have circuit directory, 110.13(A) equipment (recpts) shall be secured to surface. Called contr and left correction notice. 2/3/2005 2:38:34 PM
|
ELE04-03006
| Conference | 2/3/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | DONE |
|
|
Please call at least a half hour prior to inpsection///tom; Phone #: ###-#### Internet Inspection Request from: Barbara Moore 2/3/2005 1:10:03 PM met with elect to discuss using gutter at service, not wireway. He will change . 2/3/2005 1:30:31 PM
|
ELE05-00325
| Temporary Service | 2/3/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | PASS |
|
|
Internet Inspection Request from: Bob Glenn called contr to drive in gnd rod. t/s u/g n ok 2/3/2005 8:36:22 PM
|
ELE05-00362
| Temporary Service | 2/3/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | PASS |
|
|
mountain valley elect ###-#### t/s u/g n ok 2/3/2005 3:22:40 PM
|
ELE05-00363
| Temporary Service | 2/3/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | FAIL |
|
|
mountain valley elect ###-#### 250.24(A)(4) enclosure shall not be used as bond, Ground rod needs driven in. CALLED CONTR AND LEFT MESSAGE. 2/3/2005 3:16:23 PM
|
ELE05-00343
| Permanent Service | 2/2/2005 | 2/3/2005 | 2/3/2005 12:00:00 AM | P | PASS |
|
|
need inspection on 100 amp service, please call andy at ###-#### to set up time so you can be let in. Internet Inspection Request from: Andy Rose met elect, had him add gnd bushing to panel. 2/3/2005 1:33:29 PM
|