Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-00293 ELE-Aging Inspection2/3/20102/3/20102/8/2010 6:45:56 AM DONE
no activity, see doc expire
ELE09-00504 ELE-Aging Inspection2/3/20102/3/20102/8/2010 6:43:22 AM DONE
no activity, suc
ELE07-03996 ELE-Aging Inspection2/3/20102/3/20102/8/2010 6:41:50 AM DONE
see final, no activity
ELE10-00191 Permanent Service2/3/20102/3/20102/3/2010 5:36:22 PMPCANC
Heidi Phone #: ###-#### done by 414
ESC09-00798 General Inspection2/3/20102/3/20102/3/2010 4:15:17 PMPPASS
looked ok
ESC09-00688 General Inspection2/3/20102/3/20102/3/2010 4:14:44 PMPPASS
looked ok
ESC09-00203 General Inspection2/3/20102/3/20102/3/2010 4:14:05 PMPPASS
looked ok
ELE10-00195 Electrical Rough-In2/3/20102/3/20102/3/2010 3:15:22 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: cory carman called, left correction notice, NEC 517.13(B) switches shall be wired with mc cable with sheath qualifying as an equipment grounding conductor (receptacles also), 300.4(A)&(D) edge of bored holes and cables shall be 1 1/4" from edge of framing members, NOTE corrections shall be made within 5 working days or further action will be taken, no esc this project
ELE10-00064 Electrical Rough-In2/3/20102/3/20102/3/2010 2:10:49 PMPPASS
Grounding inspection please-Mike Phone #: ###-#### ok to cover concrete encased electrode and u/g for pump area only, no esc this project
ELE10-00196 Electrical Rough-In2/3/20102/3/20102/3/2010 1:00:35 PMPPASS
Robert ###-#### met owner, ric ok, no esc this project
ELE09-02436 Final2/3/20102/3/20102/3/2010 11:18:59 AMAPASS
acess will not be available until after 9 am please call me if this will not work. Thanks Shaun ###-#### Phone #: ###-#### Internet Inspection Request from: Shaun Kirkman ok to final, no esc this project
ELE10-00188 Rough-In Permanent Service2/2/20102/3/20102/3/2010 10:47:00 AMAPASS
Dino Phone #: ###-#### called, ric ok, p/s u/g n ok
ELE08-02858 Electrical Rough-In2/2/20102/3/20102/3/2010 9:58:59 AMACANC
Contact Paul Cushing Phone #: ###-#### Internet Inspection Request from: Deb Gooden called contractor, told to group permits, owner has to pull new permit or add work to contractors permit, no esc this project
ELE09-02256 Final2/2/20102/3/20102/3/2010 9:43:32 AMAPASS
rocky Phone #: ###-#### ok to final
ELE09-01997 Electrical Rough-In2/2/20102/3/20102/3/2010 9:13:39 AMAPART
Gene on site - ###-####
19 units and Corridor on South end only please. Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ric ok anop
ELE10-00190 Electrical Rough-In2/2/20102/3/20102/3/2010 8:49:46 AMAPART
contact: Mark Knight Phone #: ###-#### Internet Inspection Request from: Deb Gooden bath walls only anop ok to cover, no esc this project