Inspections for the day of: Wednesday, February 3, 2016.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01094 ELE-Aging Inspection2/3/20162/3/20162/4/2016 4:05:26 PM PASS
Still under construction
ELE12-00179 ELE-Aging Inspection2/3/20162/3/20162/3/2016 3:02:16 PM PASS
Still under construction
ELE16-00325 Electrical Rough-In2/2/20162/3/20162/3/2016 2:57:46 PMPPASS
Underground Conduit Inspection. Would like to request inspection after 3pm if possible. Tim ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence 2 conduits ran from south side around east side to northeast corner rough in ok cover
ELE16-00325 Electrical Rough-In2/3/20162/3/20162/3/2016 2:36:58 PMPFAIL
Underground Conduit Inspection. Would like to request inspection after 3pm if possible. Tim ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence
590.6(B)- All receptacles installed for temp power shall have GFCI protection. 40 and 50 amp 240 volt no GFCI protection.
ELE10-01304 ELE-Aging Inspection2/3/20162/3/20162/3/2016 2:30:24 PM PASS
Still under construction
ELE15-01776 Final2/3/20162/3/20162/3/2016 2:12:35 PMPPASS
Rock

I will meet you there if you call me and give me a heads up.

Mike Cole Phone #: ###-#### Inspection requested via web by Mike Cole Final ok
ELE16-00182 Final2/3/20162/3/20162/3/2016 1:19:21 PMPPASS
Phone #: ###-#### Inspection requested via web by Shane Dale
Unable to comply directly above wall due to 3 hour fire rating and moving would compromise rating, rest of new install ok. Final ok
ELE16-00209 Electrical Rough-In2/2/20162/3/20162/3/2016 11:18:43 AMAPASS
homeowner Phone #: ###-#### Not able to check junction box it was out of reach. Rough in ok
ELE16-00209 Final2/3/20162/3/20162/3/2016 11:14:34 AMPPASS
homeowner Phone #: ###-####
Final ok
ELE16-00320 Electrical Rough-In2/2/20162/3/20162/3/2016 10:43:00 AMAPASS
The access code is 8120, any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren Basement wall for bedroom rough in ok cover
ELE16-00182 Final2/3/20162/3/20162/3/2016 10:15:20 AMAFAIL
Phone #: ###-#### Inspection requested via web by Cyndi Dale
300.4(E)- Cables, Raceways, or Boxes Installed in or Under Roof Decking. A cable, raceway, or box, installed in exposed or concealed locations under metal-corrugated sheet roof decking, shall be installed and supported so there is not less than 38 mm (1 1/2 in.) measured from the lowest surface of the roof decking to the top of the cable, raceway, or box. A cable, raceway, or box shall not be installed in concealed locations in metal-corrugated, sheet decking–type roof. New cables only.
ELE15-03544 Final2/3/20162/3/20162/3/2016 10:12:38 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Craig Korell Inspection cancelled from web by: Craig Korell
ELE16-00234 Electrical Rough-In2/2/20162/3/20162/3/2016 9:45:17 AMAPASS
We need a wall cover inspection. Thank you. Dale Phone #: ###-#### Inspection requested via web by Thomas Jenkins Bedroom remodel turning 2 sleeping areas into 4 individual. Will check on AFCI requirements. Wall rough in ok cover
ELE15-03731 Final2/2/20162/3/20162/3/2016 9:12:55 AMAPASS
Please contact Gary ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Tracy Robertson Final ok