Inspections for the day of: Wednesday, February 4, 2015.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC12-00403 General Inspection2/4/20152/4/20152/4/2015 4:22:51 PM PASS
Streets surrounding JUMP project, laydown yard, and employee parking areas do not have significant trackout. Checked MS4 discharge into river and it is visibly clear. Concrete washout located within site. No corrections needed currently.
ESC12-00130 General Inspection2/4/20152/4/20152/4/2015 3:59:42 PM PASS
River's Edge vertical construction in progress. No trackout to Royal and DIs have inlet protection with remaining capacity to capture sediment. Checked MS4 out to river, no dewatering discharge or stormwater runoff flowing into river.

No corrections at this time.
ESC14-00157 General Inspection2/4/20152/4/20152/4/2015 3:22:28 PM CANC
rescheduled for 2/5
ESC14-00515 Aging Inspection2/4/20152/4/20152/4/2015 2:21:30 PM PART
WIP. Driveway is muddy but no significant trackout or evidence of muddy discharges offsite.

Need to post permit and stay off driveway while it is muddy to avoid trackout.
ESC14-00944 Random Inspection2/4/20152/4/20152/4/2015 1:31:59 PMPPASS
WIP on frame. Permit posted, no trackout, trash contained. Workers parking on street and paved drive to stay off muddy areas. No corrections needed.
ESC14-00684 Site Preparation2/3/20152/4/20152/4/2015 1:30:57 PMPPART
Note - not a site prep inspection, home already in progress, general inspection.

No trackout or blowout of sediment to streets, gutters and storm drains. Permit posted and trash is contained.

Rooftop drainage is not yet installed so runoff has created a rill erosion on slope of site. To fix slope will need to be raked and tracked or gravel check dams installed to filter out flow.

Most sediment has been trapped at perimeter wattle. Notified Bruno built contact Jeremy about the issue. Needs action before getting worse.
ESC15-00032 Site Preparation2/4/20152/4/20152/4/2015 1:09:10 PMPPART
Permit is posted. Some infill material was brought into site and sand & loose sediment is on the road. RP/GC Larry from Alturas was on site and stated it would be cleaned up today. I provided my contact information and let him know about the site prep procedure. Approved to continue, will check back on clean up efforts.
ESC14-00818 Random Inspection2/4/20152/4/20152/4/2015 12:01:24 PMPPASS
Site is currently shut down but has good perimeter controls and was cleaned up before crews left. Need to repost permit sign that has been damaged by weather.
ESC14-00753 Aging Inspection2/4/20152/4/20152/4/2015 11:43:26 AM PASS
Home is complete. Site needs landscaping/stabilization and final site cleanup. No discharges, spills, or uncontained trash. BLD already finaled.
ESC14-00753 DOC - Permit Finaled2/4/20152/4/20152/4/2015 11:35:27 AMPPASS
(This activity was added in error so we have changed the case status back to Issued.)
ESC14-00045 General Inspection2/4/20152/4/20152/4/2015 11:02:49 AM PASS
SFH near completion. Landscaping yard and interior work ongoing. Permit posted. No violations observed.
ESC14-01158 Site Preparation2/3/20152/4/20152/4/2015 10:38:19 AMAPASS
Josh Phone #: ###-####

Permit posted. Heavy rock tracking pad installed for heavy equipment that is preparing foundation. Approved to continue project. No MS4 or private stormwater facilities to protect. Just need to sweep up any trackout.
ESC13-00930 General Inspection2/4/20152/4/20152/4/2015 10:11:07 AM PASS
ESC14-00694 Aging Inspection2/4/20152/4/20152/4/2015 9:57:40 AM PASS
Homeowner RP project in progress. No sediment leaving site; permit posted in window. Approved.
ESC13-00230 General Inspection2/4/20152/4/20152/4/2015 9:25:36 AM PASS
ESC14-00791 General Inspection2/4/20152/4/20152/4/2015 9:00:54 AM PASS
WIP. No trackout to Gowen Road; permit posted on security fence (project located within airport restricted runway area). Working on putting up the hangar walls. This permit is covers the grading and drainage for the site, which is not yet complete. Vertical construction and TI build out of hangar are covered under ESC14-00941 and ESC14-01128 respectively.