Inspections for the day of: Monday, February 5, 2001.
Number of inspections: 6
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBill VanDegrift
TitlePLM-INSPECTOR
Phone #794-9372
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM00-02169 Plumbing Rough-in2/2/20012/5/20012/5/2001 12:00:00 AMPFAIL
conference only ###-#### replace avbs with pvbs and extend 12" above piping on hose reels, turn rps and dcvas so valves are out, provide rp on fish case wash and proofers, move water softenor bypass downstream of rp, label all non-potable water piping, expose airgap in all equipment, rp on beverage mechine in breakroom, set all equipment 2/5/2001 5:25:56 PM
PLM00-03360 Final2/5/20012/5/20012/5/2001 12:00:00 AMPPASS
kathy ###-####
PLM00-03360 Final2/5/20012/5/20012/5/2001 12:00:00 AMPPASS
###-####
PLM00-03573 Final2/5/20012/5/20012/5/2001 12:00:00 AMPPASS
###-####
PLM01-00181 Water and/or Sewer2/5/20012/5/20012/5/2001 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 02/05/2001 at 08:25:55. Contact: ###-####.
PLM00-03202 Plumbing Rough-in2/5/20012/5/20012/5/2001 12:00:00 AMPPART
Added by Inspector: 330 On 2/5/2001 5:27:26 PM rain drain stub out and up at col. 24 west side