Inspections for the day of: Monday, February 5, 2007.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-00390 Permanent Service2/3/20072/5/20072/5/2007 3:17:35 PMPPASS
Phone #: ###-#### corr. called for r/i 300.4 nail plates and 11/4", 110.3(B) & 314.4 needs bond bushing for steel flex where it enters plastic enclosure p/s u/g new ok
ELE07-00379 Permanent Service2/5/20072/5/20072/5/2007 2:35:19 PMPPASS
Joe - per Jack set for 1:00; Phone #: ###-#### Internet Inspection Request from: Darla Downs p/s u/g rec ok
ELE07-00397 Final2/5/20072/5/20072/5/2007 1:45:59 PMPNR
daryl; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
ELE07-00397 Electrical Rough-In2/5/20072/5/20072/5/2007 1:45:28 PMPFAIL
daryl; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
corr. called 210.52(A) shall prvide reqired outlets for spacing, 314.16 correct all box fill, 300.10&12 shall maintain elect. and mech. continunity of raceways flex from box to wall heater and wiremold, 386.2, 21, 100 shall use listed fittings for wiremold, shall not run romex in wiremold, provide abrasion protection
ELE07-00395 Permanent Service2/5/20072/5/20072/5/2007 12:43:22 PMPFAIL
Unit #6. Work performed by Ron Chaney. Phone #: ###-#### corr. called550.10(AthurH) cord shall meet requirements, cord is buried, and damaged, 550.11(D) shall provide 50 amps not 60, BCC shall make corrections or power could be diconnected
ELE06-03996 Final2/5/20072/5/20072/5/2007 12:05:46 PMPPASS
please call for access code, rock-###-#### Phone #: ###-#### ok both units
ELE07-00379 Final2/2/20072/5/20072/5/2007 10:03:40 AMACANC
Call Jim Allen for appt. to get in house. ###-#### cell, ###-#### home. Phone #: ###-#### called contr canceled
ELE07-00343 Rough-In Permanent Service2/5/20072/5/20072/5/2007 10:02:53 AMAPASS
Phone #: ###-#### r/i p/s u/g for meter ok
ELE07-00393 Electrical Rough-In2/5/20072/5/20072/5/2007 9:17:34 AMPPASS
zane ; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
r/i garage ok
ELE07-00393 Permanent Service2/5/20072/5/20072/5/2007 9:17:06 AMAPASS
zane ; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
p/s u/g new ok for garage only
ELE07-00308 Rough-In Permanent Service2/2/20072/5/20072/5/2007 9:14:18 AMAFAIL
Scheduled by a contractor via Hello! on 2/2/2007 at 12:38:33 PM. Contact: ###-####. corr. called 300.4 nail plates, 210.52(A) outlets required stair wall kit. din., liv. rm wall by entry, 250.122 needs #12 equip grd wire kit, where 12&14 are in same box, corr for low voltage. bld06-02488 300.4(A)(1)&(D) nail plates and 11/4" for cables parallel to framing members
ELE07-00368 Temporary Service2/2/20072/5/20072/5/2007 8:07:04 AMAPASS
CHAD; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
t/s u/g new ok