Inspections for the day of: Friday, February 5, 2010.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-01693 ELE-Aging Inspection2/5/20102/5/20102/9/2010 11:19:11 AM DONE
looked at signs, see final
ELE09-01624 ELE-Aging Inspection2/5/20102/5/20102/9/2010 6:47:22 AM DONE
suc
ELE07-03020 ELE-Aging Inspection2/5/20102/5/20102/9/2010 5:35:07 AM DONE
suc
ELE07-03867 ELE-Aging Inspection2/5/20102/5/20102/9/2010 5:33:34 AM DONE
no activity, see doc expire
ELE10-00212 Temporary Service2/5/20102/5/20102/8/2010 9:23:15 AMPPASS
Don ###-#### called, t/s u/g n ok
ELE10-00211 Final2/5/20102/5/20102/8/2010 8:44:19 AMPPASS
Phone #: ###-#### Internet Inspection Request from: Jim Williams temp lights ok, signed structural card, no esc this project
ELE10-00215 Electrical Rough-In2/5/20102/5/20102/8/2010 8:23:17 AMPFAIL
Chris-Late this afternoon please Phone #: ###-#### called, left message, left correction notice, NECn300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 314.20 boxes shall be flush with finished surface on outside, BCC shall install boxes and panel before cover, shall see u/g before cover, NOTE: corrections shall be msde in 5 working days or further action will be taken
ELE09-01675 Permanent Service2/5/20102/5/20102/5/2010 3:58:22 PMPFAIL
Tyler Phone #: ###-#### called, left correction notice, NEC 312.5 all conductors entering enclosures shall have abrasion protection, BCC shall provide access for inspection
ELE09-00237 Final2/5/20102/5/20102/5/2010 2:35:19 PMPFAIL
Mike Phone #: ###-#### please call 30 min before going out left correction notice, NEC 110.26(A) shall provide workspace about panel per article, 410.16(C) closet lights shall be provided with clearance per article, NOTE corrections shall be made within 5 working days or further action will be taken
ELE09-01997 Electrical Rough-In2/5/20102/5/20102/5/2010 2:13:02 PMPPART
Underground only please - AS LATE IN AFTERNOON AS POSSIBLE PLEASE!! Thank you! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ok to cover u/g for carports and west side building, no esc this project
ELE10-00090 Final2/5/20102/5/20102/5/2010 1:37:26 PMAPASS
thanks! Phone #: ###-#### Internet Inspection Request from: Darryn Coburn called, ok to final
ELE09-01911 Final2/4/20102/5/20102/5/2010 12:44:47 PMAPASS
Donald- Phone #: ###-#### ok to final
ELE10-00102 Final2/4/20102/5/20102/5/2010 10:44:03 AMAPASS
Remodel final inspection Phone #: ###-#### Internet Inspection Request from: Zane Robertson ok to final
ELE10-00132 Final2/4/20102/5/20102/5/2010 10:28:30 AMAPASS
labeled breaker correctly - all power works on existing reception wall. Phone #: ###-#### Internet Inspection Request from: Andy Rose corrections made, ok to final,signed card, no esc this project
ELE10-00207 Final2/4/20102/5/20102/5/2010 10:26:45 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Debby Ellis ok to final, signed occupancy card, no esc this project
ELE10-00091 Final2/4/20102/5/20102/5/2010 10:04:42 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson ok to final, called structural, said ok to final electrical, signed card, no esc this project
ELE10-00004 Permanent Service2/4/20102/5/20102/5/2010 9:29:34 AMACANC
Jared Phone #: ###-#### see conference
ELE10-00004 Conference2/5/20102/5/20102/5/2010 9:29:16 AMADONE
Jared Phone #: ###-#### went over requirement for individual buildings by structural or can't have more than 1 service
ELE09-02310 Electrical Rough-In2/4/20102/5/20102/5/2010 9:12:41 AMAPASS
Jason Phone #: ###-#### ok to cover u/g , no esc this project
ELE09-02278 Electrical Rough-In2/4/20102/5/20102/5/2010 8:52:29 AMAPART
Contact: Tony Holt Phone #: ###-#### Internet Inspection Request from: Deb Gooden kitchen walls and hard lids except panel wall only ok to cover anop, no esc this project
ELE10-00165 Conference2/3/20102/5/20102/5/2010 8:27:41 AMADONE
Cheryl Phone #: ###-#### met owner talked about 1/14" and new circuits and j-boxes, no esc this project