ELE12-01598
| ELE-Aging Inspection | 2/5/2014 | 2/5/2014 | 2/5/2014 4:19:39 PM | | DONE |
|
|
Called contractor will schedule final
|
ELE14-00283
| Conference | 2/4/2014 | 2/5/2014 | 2/5/2014 4:15:40 PM | P | DONE |
|
|
Late afternoon please - Pat Phone #: ###-#### Discussed trench depth, 1 1/4" rule, stapling, and inspection process
|
ELE11-01343
| Final | 1/29/2014 | 2/5/2014 | 2/5/2014 3:19:57 PM | P | FAIL |
|
|
Please call homeowner when you are on the way, home phone is: ###-#### Phone #: ###-#### >> Inspection requested via web by Louis Keller Generator added, Feeders from transfer switch t main breaker panel vary in size. 1/0 from meter to transfer switch, transfer switch to panel 1/0 and # 1 on 175 amp main breaker. 310.15 (B)(6)- 1/0 minimum for residential service feeders.
|
ELE13-03249
| Electrical Rough-In | 2/5/2014 | 2/5/2014 | 2/5/2014 2:24:20 PM | P | PASS |
|
|
Contact: Frank Yantis. ceiling inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden Ceiling by oven rough in ok cover
|
ELE13-03329
| Final | 2/4/2014 | 2/5/2014 | 2/5/2014 2:10:12 PM | A | PASS |
|
|
Garage Code 1979E Phone #: ###-#### >> Inspection requested via web by Alan Lusk Final ok
|
ELE13-03399
| Electrical Rough-In | 2/5/2014 | 2/5/2014 | 2/5/2014 2:09:11 PM | P | PASS |
|
|
Men and womens bathroom ceiling rough in ok cover
|
ELE13-03399
| Final | 2/4/2014 | 2/5/2014 | 2/5/2014 2:08:29 PM | A | CANC |
|
|
Contact: Frank Yantis ceiling inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden Needed rough in inspection
|
ELE12-01605
| Final | 2/5/2014 | 2/5/2014 | 2/5/2014 1:46:45 PM | P | PASS |
|
|
Sign UL listing confirmed. Final ok
|
ELE12-01605
| Electrical Rough-In | 2/5/2014 | 2/5/2014 | 2/5/2014 1:46:03 PM | P | PASS |
|
|
Sign rough in ok
|
ELE13-01937
| Final | 2/5/2014 | 2/5/2014 | 2/5/2014 1:30:08 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dana Vance UL listing confirmed. Final ok
|
ELE13-01937
| Electrical Rough-In | 2/5/2014 | 2/5/2014 | 2/5/2014 1:29:40 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dana Vance Sign rough in ok
|
ELE13-03407
| Electrical Rough-In | 2/5/2014 | 2/5/2014 | 2/5/2014 12:58:40 PM | P | PASS |
|
|
please inspect floor heat in upstairs master bathroom. Please call half an hour before inspection to insure access thanks Shaun ###-#### Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Floor heat rough in ok cover
|
ELE12-01756
| Permanent Service | 2/5/2014 | 2/5/2014 | 2/5/2014 12:16:13 PM | P | PASS |
|
|
Noble Dunn-Please call prior to inspection Phone #: ###-#### p/s o/h rec ok
|
ELE11-01976
| ELE-Aging Inspection | 2/5/2014 | 2/5/2014 | 2/5/2014 10:46:30 AM | | DONE |
|
|
Waiting on owner
|
ELE11-01876
| ELE-Aging Inspection | 2/5/2014 | 2/5/2014 | 2/5/2014 10:43:22 AM | | DONE |
|
|
Waiting on owner
|
ELE13-02057
| Electrical Rough-In | 2/4/2014 | 2/5/2014 | 2/5/2014 9:39:49 AM | A | PASS |
|
|
Robert. 6th floor ceiling cover. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy ^th floor corridor grid and elevator hardlid rough in ok cover
|
ELE13-03065
| Final | 2/4/2014 | 2/5/2014 | 2/5/2014 8:55:34 AM | A | PASS |
|
|
6829 garage code Phone #: ###-#### >> Inspection requested via web by Neal Rumsey Final ok
|
ELE13-03565
| Final | 2/4/2014 | 2/5/2014 | 2/5/2014 8:39:42 AM | A | FAIL |
|
|
garage code 6933 Phone #: ###-#### >> Inspection requested via web by Neal Rumsey 210.52- Minimum required receptical outlets not compliant in master bed. 17' between outlets.
|