ELE19-00448
| Electrical Rough-In | 2/5/2019 | 2/5/2019 | 2/5/2019 2:43:53 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Jason Wicks 300.4- Where NM cables are run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected from damage by nail plates. Above panel and near door to house. 334.30- Flat cables shall not be stapled on edge.
|
ELE19-00432
| Final | 2/4/2019 | 2/5/2019 | 2/5/2019 2:01:35 PM | P | FAIL |
|
|
Please give a call when on the way ###-#### Inspection requested via web by Same Electric 314.25- All boxes shall have covers. Kitchen counter boxes unfinished around sink area and atrium. Complete all counter top devices. 422.30- A disconnecting means shall be provided for built in oven. 110.25 lockout acceptable.
|
ELE19-00447
| Final | 2/5/2019 | 2/5/2019 | 2/5/2019 1:15:40 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Matthew White Final ok
|
ELE19-00447
| Electrical Rough-In | 2/5/2019 | 2/5/2019 | 2/5/2019 1:14:58 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Matthew White Replaced feeders from service to mobile home. Trenched to under mobile home then ran on surface to panel location and installed flexible connection to hook up. Underground rough in ok cover
|
ELE18-04731
| Final | 2/4/2019 | 2/5/2019 | 2/5/2019 10:54:38 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Thomas wilson Final ok
|
ELE19-00216
| Final | 2/4/2019 | 2/5/2019 | 2/5/2019 10:54:05 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Thomas wilson Final ok
|
ELE19-00441
| Electrical Rough-In | 2/5/2019 | 2/5/2019 | 2/5/2019 10:37:55 AM | A | PASS |
|
|
Ok to cover walls. Any questions contact Rustin. Lock box on North rain downspout, code is 8463 Phone #: ###-#### Inspection requested via web by Dean Gernaat Wall rough in ok cover
|
ELE19-00414
| Temporary Service | 2/4/2019 | 2/5/2019 | 2/5/2019 9:24:52 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Schaffer t/s u/g n ok
|