PLM18-04286
| Final | 2/5/2019 | 2/5/2019 | 2/5/2019 3:13:32 PM | P | PASS |
|
|
key is in front of the house electric box Phone #: ###-#### Inspection requested via web by casey lattimer
|
PLM18-04287
| Final | 2/5/2019 | 2/5/2019 | 2/5/2019 3:12:54 PM | P | PASS |
|
|
key is in front of house electric box Phone #: ###-#### Inspection requested via web by casey lattimer
|
MEC19-00102
| Pressure Test | 2/4/2019 | 2/5/2019 | 2/5/2019 2:37:14 PM | P | PASS |
|
|
field super; Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney-20 lb gas test pass.
|
MEC19-00102
| Rough-in | 2/4/2019 | 2/5/2019 | 2/5/2019 2:35:52 PM | P | PASS |
|
|
field super; Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC19-00099
| Pressure Test | 2/4/2019 | 2/5/2019 | 2/5/2019 2:35:39 PM | P | PASS |
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney-20 lb gas test pass.
|
MEC19-00099
| Rough-in | 2/4/2019 | 2/5/2019 | 2/5/2019 2:35:07 PM | P | NR |
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney-Need to finish rough-in.
|
MEC19-00417
| Final | 2/5/2019 | 2/5/2019 | 2/5/2019 2:20:26 PM | P | PART |
|
|
Call ahead to Carol at ###-#### when in route. Phone #: ###-#### Inspection requested via web by Sabrina DeHority-When ventless fireplace is installed call in for final. Need to add fireplace to permit. Furnace pass.
|
PLM19-00508
| Plumbing Rough-in | 2/5/2019 | 2/5/2019 | 2/5/2019 1:40:16 PM | P | FAIL |
|
|
Please contact Bill on your way out. ###-#### Use side gate on south side of house. Phone #: ###-#### Inspection requested via web by Vance Poulsen-Need to test DWV. Need to tent waterline in attic space. Cannot s-trap shower. Cross santee for vent installed in wrong direction. Santees are not approved for drainage in the horizontal. Need to vent toilet & shower per the 2017 ISPC. Need 3" base of stack cleanout. Need to be 6" above flood level rim before tieing horizontal vents together. Traps for wash basins need to be same size as trap arms.
|
PLM18-04729
| Final | 2/5/2019 | 2/5/2019 | 2/5/2019 12:45:45 PM | P | PASS |
|
|
9378 Phone #: ###-#### Inspection requested via web by Semsudin Konjuhovac
|
PLM19-00450
| Final | 2/4/2019 | 2/5/2019 | 2/5/2019 11:54:20 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
PLM19-00508
| Water and/or Sewer | 2/5/2019 | 2/5/2019 | 2/5/2019 11:34:42 AM | P | CANC |
|
|
Please contact Bill on your way out. ###-#### Use side gate on south side of house. Phone #: ###-#### Inspection requested via web by Vance Poulsen
|
PLM18-02417
| Final | 2/4/2019 | 2/5/2019 | 2/5/2019 11:32:45 AM | A | PASS |
|
|
Please call Mark, This is the new Nitro Plant at the far S.E. corner. Thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
|
PLM18-04058
| Final | 2/5/2019 | 2/5/2019 | 2/5/2019 10:43:19 AM | P | PASS |
|
|
homeowner wants a PM inspection-he said all inspection were done
|
PLM18-04431
| Final | 2/4/2019 | 2/5/2019 | 2/5/2019 9:43:08 AM | A | PASS |
|
|
7352 Phone #: ###-#### Inspection requested via web by robert goodson
|
PLM18-04115
| Final | 2/4/2019 | 2/5/2019 | 2/5/2019 9:42:44 AM | A | PASS |
|
|
7352 Phone #: ###-#### Inspection requested via web by robert goodson
|
MEC19-00408
| Rough-in | 2/4/2019 | 2/5/2019 | 2/5/2019 9:41:43 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero
|
MEC19-00461
| Final | 2/4/2019 | 2/5/2019 | 2/5/2019 9:26:19 AM | A | PASS |
|
|
field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC19-00371
| Pressure Test | 2/4/2019 | 2/5/2019 | 2/5/2019 9:12:15 AM | A | PASS |
|
|
Call jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek-20 lb gas test pass.
|
MEC19-00371
| Rough-in | 2/4/2019 | 2/5/2019 | 2/5/2019 9:11:45 AM | A | PASS |
|
|
Call jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
|
PLM18-04057
| Final | 2/4/2019 | 2/5/2019 | 2/5/2019 8:51:07 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Smith
|
PLM18-04286
| Final | 2/4/2019 | 2/5/2019 | 2/5/2019 8:13:52 AM | A | FAIL |
|
|
key is in front of the house electric box Phone #: ###-#### Inspection requested via web by casey lattimer-Cannot S-trap wash basins. Need to 90 down T&P & pan drain.
|
PLM18-04287
| Final | 2/4/2019 | 2/5/2019 | 2/5/2019 8:13:26 AM | A | FAIL |
|
|
key is in front of house electric box Phone #: ###-#### Inspection requested via web by casey lattimer-Cannot S-trap wash basins. Need to 90 down T&P & pan drain.
|
PLM18-04058
| Final | 2/4/2019 | 2/5/2019 | 2/5/2019 7:14:56 AM | A | CANC |
|
|
homeowner wants a PM inspection-he said all inspection were done
|