Inspections for the day of: Friday, February 6, 1998.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorCarl Dependahl
TitleBLD-COM/RES INSPECTOR
Phone #794-9492
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC98-00310 INSP - Framing/ Rough-in2/5/19982/6/19982/6/1998 12:00:00 AMAPART
duct work at motel...looks ok. told to recall as its comm'l.
BLD97-00494 INSP - Conference2/6/19982/6/19982/6/1998 12:00:00 AMAPASS
re final insps, told to call office.
BLD97-00688 INSP - Final2/6/19982/6/19982/6/1998 12:00:00 AMPFAIL
DOOR OPEN--GARY ###-####
BLD97-01848 INSP - Framing/Rough-in2/10/19982/6/19982/6/1998 12:00:00 AMPNR
STOPPED BY JOB, NO PERMIT POSTED, ETC, LEFT NOTE.
BLD97-02911 INSP - Framing/Rough-in2/6/19982/6/19982/6/1998 12:00:00 AMPFAIL
late; restroom area...COMPLETE FIREBLOCKS, REMOVE INSUL FACE PAPER,ETC...NEED SP[EC. INSP. REPORTS IN TIMELY MANNER. OK TO COVER FURRED WALLS AT RESTROOMS ONLY
BLD97-03386 INSP - Wall cover2/9/19982/6/19982/6/1998 12:00:00 AMPPART
1HR AT ROOF FRAMING
BLD97-03512 INSP - Framing/Rough-in2/6/19982/6/19982/6/1998 12:00:00 AMPFAIL
viking motel...COMPLETE FIREBLOCKS AND DRAFT STOP (SEAL GAPS) NEED ATTIC ACCESS
BLD96-01709 INSP - Carpentry2/6/19982/6/19982/6/1998 12:00:00 AMPPART
w/ dom...REC'D ENG'S LETTER RE SHEARWALLS (AND RECOMMENDATION TO LAG MAIN INT WALL TO CRIPPLE WALL...NOT DONE YET) REQ'S STAMP ARCH'S LETTER FOR ROOF CHANGE FROM TILE TO COMP...NEED TO COMPLETE DRAFT STOP, RECOMMEND CONTACT ARCH. FOR DESIGN HELP
MEC97-03877 INSP - Final2/6/19982/6/19982/6/1998 12:00:00 AMPPASS
Scheduled by Hello!. Contact phone is [3426813].
MEC97-03877 INSP - Final2/6/19982/6/19982/6/1998 12:00:00 AMPPASS
Scheduled by Hello!. Contact phone is [3426813].