ELE14-02796
| Final | 2/6/2015 | 2/6/2015 | 2/6/2015 3:42:29 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Thomas Jenkins 210.8- Mech rm GFCI protect receptacle located with in 6' of sink. 110.24- Available fault current shall be posted on service. 406.5- Receptacle outlets shall be secured in place. Outdoor by east door.
No card posted. Temporary final ok
|
ELE07-02082
| ELE-Aging Inspection | 2/6/2015 | 2/6/2015 | 2/6/2015 3:37:27 PM | | DONE |
|
|
Still under construction
|
ELE15-00321
| Final | 2/6/2015 | 2/6/2015 | 2/6/2015 3:06:37 PM | P | PASS |
|
|
###-#### Final ok
|
ELE15-00321
| Permanent Service | 2/6/2015 | 2/6/2015 | 2/6/2015 3:06:21 PM | P | PASS |
|
|
###-#### Underground shallow due to rock hit and installed in rigid conduit. p/s u/g n ok
|
ELE14-02213
| Electrical Rough-In | 2/6/2015 | 2/6/2015 | 2/6/2015 2:55:43 PM | P | PASS |
|
|
Mike Phone #: ###-#### Grid in exam rooms and exam corridors rough in ok cover
|
ELE15-00320
| Conference | 2/6/2015 | 2/6/2015 | 2/6/2015 12:54:41 PM | P | DONE |
|
|
Discussed the discovery of illegal wiring through out entire house. Boise Municiplal Code Section 4-05-32 CODE VIOLATION NOT TO BE RETAINED When altering a pre-existing electrical wire, equipment, apparatus or fixture, or adding any new wiring, the existing electrical wiring in close proximity shall be in accordance with the present code. (6338, Added, 08/03/2004) Section 4-05-23 UNLAWFUL TO CONCEAL It shall be unlawful for any person, to cover up or in any way conceal any electrical wiring, cables, conduits or other equipment until the same has been inspected and approved by an Electrical Inspector. (6338, Added, 08/03/2004) Section 4-05-29 RESPONSIBILITY Regardless of any approval issued by the City of Boise, the owner or authorized agent shall have ultimate responsibility to comply with all articles of this Code. Boise City officials, employees or agent, shall not be held liable by reason of the issuance of any permit, inspection or by reason of any final inspection approval issued by the Electrical Inspector. (6338, Added, 08/03/2004
|
ELE15-00321
| Permanent Service | 2/5/2015 | 2/6/2015 | 2/6/2015 11:42:04 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Don Conley 250.24- Premisis wiring shall have a grounding electode system conductor connected to the grounded conductor at each service. 250.92-Standard locknuts and bushings shall not be only means of bonding metal raceway on supply side of service.
|
ELE15-00203
| Electrical Rough-In | 2/5/2015 | 2/6/2015 | 2/6/2015 10:30:30 AM | A | PASS |
|
|
Underground cover inspection. North West corner of the Edwards complex. Danny is the on site contact. Phone #: ###-#### Inspection requested via web by Buster Bowen Under ground for sign located on N.W. corner near chuck-a-rama rough in ok cover
|
ELE15-00271
| Electrical Rough-In | 2/5/2015 | 2/6/2015 | 2/6/2015 9:39:06 AM | A | PART |
|
|
Von. Pony deli wall ; wall on the right side of the pony wall. New deli department. Phone #: ###-#### Inspection requested via web by Sean DeLacy Called contractor to inform of broken PVC near back corner where fllor opened up for refrigeration lines. Wall in back corner of deli rough in ok cover
|
ELE15-00272
| Final | 2/5/2015 | 2/6/2015 | 2/6/2015 9:08:10 AM | A | PASS |
|
|
garage door code: 3655 front door code: 25579 Phone #: ###-#### Inspection requested via web by Richard Gratiot Final ok
|
ELE14-02186
| Conference | 2/6/2015 | 2/6/2015 | 2/6/2015 8:49:26 AM | P | DONE |
|
|
Per phone conversation. Owner called to ask if addition of ground rods to grounding electode system location in crawl space was an acceptable location. Flooring removed to allow access for vertical installation of ground rods. told owner if rods were able to be installed vertically location is acceptable.
|
ELE15-00284
| Temporary Service | 2/5/2015 | 2/6/2015 | 2/6/2015 8:45:45 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE15-00317
| Final | 2/5/2015 | 2/6/2015 | 2/5/2015 3:52:38 PM | A | CANC |
|
|
Power off for more than 1 year.
Lock Box - OCN
Front Door - 35421 Phone #: ###-#### >> Inspection requested via web by steve ragan Inspection cancelled from web by: steve ragan
|