Inspections for the day of: Friday, February 6, 2015.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorCevyn Recla
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-03237 Final2/6/20152/6/20152/6/2015 2:42:25 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov
corrections made ?Final OK
ELE15-00255 Electrical Rough-In2/6/20152/6/20152/6/2015 2:21:30 PMPPASS
Remodel the basement Phone #: ###-#### Inspection requested via web by Neal Rumsey
basement ri ok to cover
ELE15-00300 Permanent Service2/4/20152/6/20152/6/2015 1:27:11 PMPPASS
Please make this inspection for later in the afternoon. Phone #: ###-#### Inspection requested via web by Thomas Jenkins
PS, OH, N, OK
ELE14-02714 Final2/5/20152/6/20152/6/2015 12:59:42 PMPPASS
Phone #: ###-#### Inspection requested via web by Emmet Bushman
Final OK
GCE15-00019 GCE-Permanent Service2/6/20152/6/20152/6/2015 12:09:38 PMPPASS
Bill ###-#### or ###-####
PS, OH, N< Ok
ELE15-00316 Electrical Rough-In2/6/20152/6/20152/6/2015 11:26:49 AMPPASS
Phone #: ###-#### Inspection requested via web by Emmet Bushman
check for multi wire handle tie at final, RI ok to cover
ELE12-00762 ELE-Aging Inspection2/6/20152/6/20152/6/2015 10:51:58 AM DONE
ELE12-00762 Final2/6/20152/6/20152/6/2015 10:51:49 AMPPASS
Work completed on second permit. See ele12-00779
ELE14-03266 Electrical Rough-In2/5/20152/6/20152/6/2015 10:21:24 AMAPASS
soffit inspection Phone #: ###-#### Inspection requested via web by Chris Chesnut
soffits ok to cover
ELE15-00320 Conference2/5/20152/6/20152/6/2015 9:57:11 AMADONE
Calvin will be there. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan
discussion of knob and tube, open splices, hidden junctions, previous repairs, and past permitting on the job.
ELE12-00804 ELE-Aging Inspection2/6/20152/6/20152/6/2015 9:40:18 AM DONE
Posted site, 2-6-15 9:40 am
ELE15-00313 Temporary Service2/5/20152/6/20152/6/2015 9:27:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn
TS, UG, N, OK
ELE15-00314 Temporary Service2/5/20152/6/20152/6/2015 9:25:23 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn
TS, UG, N, oK
ELE15-00316 Electrical Rough-In2/5/20152/6/20152/6/2015 9:16:11 AMAFAIL
New kitchen wiring Phone #: ###-#### Inspection requested via web by Emmet Bushman called contractor
300.13 (B) Device Removal. In multiwire branch circuits, the
continuity of a grounded conductor shall not depend on
device connections such as lampholders, receptacles, and
so forth, where the removal of such devices would interrupt
the continuity
300.4 1 nm through bored holes shall have protection where edge of hole is less than 1 1/4 inch from edge of framing member
300.4 2 where cable is run through notches in wood, it shall be protected by steel plate
210.4 B multi wire branch circuits shall have means to disconnect all ungrounded conductors simultaneously
ELE15-00315 Final2/5/20152/6/20152/6/2015 8:45:21 AMAPASS
###-#### please call karen 30 minutes in advance for access Phone #: ###-#### Inspection requested via web by danny perrin
Final OK
ELE15-00315 Permanent Service2/6/20152/6/20152/6/2015 8:44:37 AMPPASS
###-#### please call karen 30 minutes in advance for access Phone #: ###-#### Inspection requested via web by danny perrine
PS, UG, RC, OK
ELE12-02468 ELE-Aging Inspection2/6/20152/6/20152/6/2015 6:09:16 AM DONE
Talked to electrical contractor, project is back under construction and should be finishing soon
ELE15-00160 Permanent Service2/5/20152/6/20152/5/2015 3:05:11 PMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov
PS, UG, N, ok