ELE06-00199
| Final | 2/7/2006 | 2/7/2006 | 2/7/2006 4:22:18 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: joe wheeler cor. called 410.14(B) shall provide access to box behind fixture bathrm
|
ELE06-00422
| Electrical Rough-In | 2/6/2006 | 2/7/2006 | 2/7/2006 4:04:03 PM | P | CANC |
|
|
any questions please call Matt Beglan; Phone #: ###-#### Internet Inspection Request from: Jeff Radford called I rescheduled inspection for 02-08-06 AM at the request of contractor because his electrician quits work at 3:30 Pm and he wanted to be at job site when I do inspection
|
ELE05-03215
| Permanent Service | 2/7/2006 | 2/7/2006 | 2/7/2006 3:28:45 PM | P | PASS |
|
|
Rick; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong p/s u/g new ok
|
ELE05-04285
| Electrical Rough-In | 2/6/2006 | 2/7/2006 | 2/7/2006 2:57:08 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 2/6/2006 at 3:36:35 PM. Contact: ###-####. ceilings ok
|
ELE05-03999
| Final | 2/7/2006 | 2/7/2006 | 2/7/2006 1:51:05 PM | P | PASS |
|
|
perm occupancy ok question on xray listing verified no card at site
|
ELE05-03582
| Final | 2/7/2006 | 2/7/2006 | 2/7/2006 1:36:26 PM | P | FAIL |
|
|
Brandon; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong cor. called 210.11(C)(3) pantry outlet shall not be on bath circuit, no power to recept below window in kit (counter) secure outside cover so they don't fall off when testing recept
|
ELE06-00395
| Permanent Service | 2/7/2006 | 2/7/2006 | 2/7/2006 12:16:42 PM | P | PASS |
|
|
chad; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa p/s only p/s o/h rec. ok
|
ELE06-00423
| Electrical Rough-In | 2/6/2006 | 2/7/2006 | 2/7/2006 10:49:24 AM | A | FAIL |
|
|
###-#### - brandon cor. called 300.4 nail plates & 11/4" inside and outside edges of studs, 314.20 outside box shall be flush with siding, 314.17 needs conn for romex at bell box, still needs u/g inspection
|
ELE06-00199
| Electrical Rough-In | 2/6/2006 | 2/7/2006 | 2/7/2006 10:12:52 AM | A | PASS |
|
|
ceiling inspection; Phone #: ###-#### Internet Inspection Request from: joe wheeler ok
|
ELE06-00421
| Final | 2/6/2006 | 2/7/2006 | 2/7/2006 9:53:12 AM | A | FAIL |
|
|
please do a final inspection.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH needs clearence over roof 2" mast, bring grounding up to code and clearence for panel note no violations to be retained called cor. posted
|
ELE05-03127
| Electrical Rough-In | 2/6/2006 | 2/7/2006 | 2/7/2006 9:14:40 AM | A | PASS |
|
|
John; Phone #: ###-#### Internet Inspection Request from: Elizabeth basement and kit ok
|
ELE06-00165
| Electrical Rough-In | 2/6/2006 | 2/7/2006 | 2/7/2006 8:39:43 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 2/6/2006 at 3:49:56 PM. Contact: ###-####. phone , power u/g in building slab
|
ELE05-04417
| ELE-Aging Inspection | 2/7/2006 | 2/7/2006 | 2/7/2006 8:16:51 AM | | PART |
|
|
wsuc
|
ELE06-00395
| Electrical Rough-In | 2/7/2006 | 2/7/2006 | 2/7/2006 12:00:00 AM | P | PART |
|
|
chad; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa p/s ok still needs to address sub panel , feeds to range and dryer
|
ELE05-03127
| Rough-In Permanent Service | 2/6/2006 | 2/7/2006 | 2/6/2006 4:23:02 PM | A | CANC |
|
|
John; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong Inspection cancelled from web by: Elizabeth Esong
|