Inspections for the day of: Tuesday, February 7, 2017.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD16-00925 BLD-Aging Inspection2/7/20172/7/20172/15/2017 1:29:13 PM NR
HANDRAIL REQUIRED
BLD16-00988 BLD-Aging Inspection2/7/20172/7/20172/15/2017 1:28:02 PM PASS
NO REQUIST FOR PLM AND BLD EXPIERS 3/25
BLD12-01802 BLD-Aging Inspection2/7/20172/7/20172/15/2017 1:24:14 PM PASS
BLD16-02258 BLD-Aging Inspection2/7/20172/7/20172/15/2017 1:22:02 PM DONE
MIS16-00330 MIS-Aging Inspection2/7/20172/7/20172/14/2017 4:46:12 PM DONE
MIS15-00278 MIS-Aging Inspection2/7/20172/7/20172/14/2017 4:39:35 PM FAIL
Expired
(TRINITY TRAILER MANUFACTURING - Bldg #1) Permit for the construction of a new 3,800 sq. ft. two story office building with 2,050 on the first story and 1,750 sq. ft. on the second story. The first story consists of a break room accessible restrooms and a parts room area. the second story consists of restroom and office area. The building is not fire sprinklered. The new building is approximately 6 feet from an existing 16,500 sq. ft. F-2 manufactuting building and is considered one building. The enclosed stairs a the north end of the building are not required to be rated as 50% of the exits from the second story are allowed to be at unenclosed stairways per section 1016.1 #2. CDM
BLD13-02214 Expired
(TRINITY TRAILER MANUFACTURING - Bldg #2) Permit for the construction of a new 3,400 sq. ft. two story office building with 1,850 sq. ft. on the first story and 1,550 on the second story. The first story consists of a break room, accessible restrooms and a parts room. The second story consists of office area and one restroom. This building is not fire sprinklered. The new building is being placed 8' away from an existing 18,750 sq. ft. F-1 manufacturing building. The two buildings have been calculated as one building for height and area. The enclosed stairs a the north end of the building are not required to be rated as 50% of the exits from the second story are allowed to be at unenclosed stairways per section 1016.1 #2. CDM
BLD16-01532 Under Review
**see attached ACHD***(TRINITY TRAILERS - Detached accessory Membrane Structures) Permit to construct three membrane structures on an existing lot. Each structure is approximatly 2,520 square feet creating a combined square feet of 7,560. Note: these structures were permitted without a permit and are now going through the process to permit these as new structures. **TLW**
BLD16-03301 Received
**see attached ACHD***(TRINITY TRAILERS - Detached accessory Membrane Structures) Permit to construct three membrane structures on an existing lot. Each structure is approximatly 2,520 square feet creating a combined square feet of 7,560. Note: these structures were permitted without a permit and are now going through the process to permit these as new structures. **TLW**
BLD16-03302 Under Review
**see attached ACHD***(TRINITY TRAILERS - Detached accessory Membrane Structures) Permit to construct three membrane structures on an existing lot. Each structure is approximatly 2,520 square feet creating a combined square feet of 7,560. Note: these structures were permitted without a permit and are now going through the process to permit these as new structures. **TLW**
BLD16-00856 BLD-Final2/6/20172/7/20172/7/2017 4:16:11 PMPNR
would like call ahead; Victor Phone #: ###-####
BLD16-03487 BLD-Final2/6/20172/7/20172/7/2017 4:15:51 PMPPASS
Cameron Phone #: ###-####
BLD16-03487 DOC - Permit Finaled2/7/20172/7/20172/7/2017 4:15:40 PMPPASS
BLD16-03372 BLD-Final2/1/20172/7/20172/7/2017 3:44:30 PMPPASS
brandon Phone #: ###-####
BLD16-03372 DOC - Permit Finaled2/7/20172/7/20172/7/2017 3:44:13 PMPPASS
BLD16-02731 BLD-Final2/7/20172/7/20172/7/2017 1:27:24 PMPNR
Phone #: ###-#### Inspection requested via web by Christophe Heinz
BLD16-03191 BLD-Final2/6/20172/7/20172/7/2017 11:08:47 AMAPASS
After 9 // Dan Phone #: ###-####
BLD16-03191 DOC - Permit Finaled2/7/20172/7/20172/7/2017 11:08:36 AMPPASS
BLD16-03443 BLD-Wall Bracing2/6/20172/7/20172/7/2017 10:39:29 AMAPASS
Shear // Sam Phone #: ###-####exterior nailling ok need hd hardware at framing
BLD16-02207 BLD-Framing/Rough-in2/6/20172/7/20172/7/2017 10:16:37 AMAPASS
nathan Phone #: ###-####
BLD17-00077 BLD-Framing/Rough-in2/6/20172/7/20172/7/2017 9:47:11 AMAPASS
Dave Phone #: ###-#### have arch adress door swinging over step west exit. for final