Inspections for the day of: Wednesday, February 7, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-01420 Final2/7/20182/7/20182/9/2018 11:10:15 AMPPASS
CONTACT - JOHN BUSS - ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
Verified RP is cerified.
PLM18-00542 Water Heater Final2/7/20182/7/20182/7/2018 3:09:34 PMPFAIL
EARLY PM INSPECTION IF POSSIBLE PLEASE
THANK YOU Phone #: ###-#### Inspection requested via web by Aaron Alandt.
The insulation in the wall is cutting off half of the combustion air. Remove insulatioin, reschedule and call me and I'll pass it. The water heater is already stickered.
PLM17-04443 Water and/or Sewer2/7/20182/7/20182/7/2018 2:51:09 PMPPASS
sewer ok
PLM17-02818 Final2/7/20182/7/20182/7/2018 2:31:26 PMPFAIL
Jim Phone #: ###-####.
The water heater t&p must drain to the exterior of the house.
Use an approved tail piece/trap under the lav. Flex not approved.
PLM17-04574 Final2/5/20182/7/20182/7/2018 2:11:26 PMPPASS
After 1 pm plz Phone #: ###-#### Inspection requested via web by Scott Myers
PLM17-02263 PLM-Aging Inspection2/7/20182/7/20182/7/2018 11:03:52 AM PASS
PLM17-02263 DOC - Permit Finaled2/7/20182/7/20182/7/2018 11:03:35 AMPPASS
passed
PLM17-01420 PLM-Aging Inspection2/7/20182/7/20182/7/2018 11:02:36 AM PEND
Becca to schdule.
PLM17-04445 Water and/or Sewer2/6/20182/7/20182/7/2018 10:52:16 AMAPASS
Phone #: ###-#### Inspection requested via web by David Scaggs. Sewer ok to cover
PLM17-04444 Water and/or Sewer2/6/20182/7/20182/7/2018 10:51:40 AMAPASS
Phone #: ###-#### Inspection requested via web by David Scaggs. Sewer ok to cover
PLM17-04443 Water and/or Sewer2/6/20182/7/20182/7/2018 10:50:26 AMANR
Phone #: ###-#### Inspection requested via web by David Scaggs
PLM17-01432 PLM-Aging Inspection2/7/20182/7/20182/7/2018 8:10:16 AM PEND